45 - iRIS 220 / iRIS 320, V1.19 User Guide
System Status 3 Screen (Level 1)
The System Status 3 screen is always available, no matter what level of access has been selected. The information shown on this screen includes the voltage being measured at the AI1 – AI4 terminals in millivolts. These values are useful for checking input signals and also for the calibration process.
AI1: 1754 mV
AI2: 682 mV
AI3: 1754 mV
AI4: 682 mV
- | Move back to System Status 2 screen |
+ | Move forward to System Status 4 screen |
| otherwise unused. |
Enter | Move down to Main Menu screen |
Alt Enter | Log in (If PIN code <> 0), otherwise unused |
System Status 4 Screen (Level 1)
The System Status 4 screen is also always available, no matter what level of access has been selected. The information shown on this screen includes the current status of the digital inputs and outputs (0=OFF, 1=ON). This screen shows the current SOD and EOD pointer values.
DI1:0 DI2:1 DO1:1 DO2:0 SOD: 177104 EOD: 177336
- | Move back to System Status 3 screen |
+ | Unused |
Enter | Move down to Main Menu screen |
Alt Enter | Log in (If PIN code <> 0), otherwise unused |
Main Menu Screen (Level 2)
The Main Menu screen is used to select which type of information you want to look at.
MAIN MENU >Sensors Totals Comms
+/- | Move down/up through menu |
Enter | Select menu item |
Alt Enter | Move up to System Status 1 screen |
5.2.6 Sensor Related Screens
Sensor Status Screen (Level 3)
This screen provides an overview of each sensor.
Line 1 indicates sensor ID, data source and its composite status including:
‘.’ if sensor is enabled
‘:’ if sensor and alarm(s) are enabled
‘*’ if sensor and alarm(s) are enabled and alarm(s) currently active Line 2 indicates the raw input value.
Line 3 indicates the scaled (engineering unit’s) value. Line 4 indicates the last logged value.
1:Bat Volt
→1257
←12.57
↓ 1262
+/- | Move forwards/backwards through sensors |
Enter | Drill down to Sensor Menu screen |