LCD Failure
If the LCD fails, perform the following actions one at a time to correct the problem. Do not replace non- defective FRUs:
Start
OK
Check LCD | NG | |
Module | ||
|
Swap LCD panel/
LCD cable
ok
Swap M/B
Built-In Keyboard Failure
If the
START
Keyboard FPC |
|
|
| No | |
well connected? |
| |
|
|
Connect it well
Keyboard OK? | No |
Replace keyboard
Replace M/B
Chapter 4 | 143 |