Panasonic AJ-HD3000 manual ∑ Setting the RS-232C parameters, ∑ Setting the V/A control parameters

Models: AJ-HD2700 AJ-HD3700BE AJ-HD3700A AJ-HD2000 AJ-HD3000 AJ-HD3700

1 194
Download 194 pages 24.4 Kb
Page 126
Image 126

INTERFACE SET UP menu

Setting the RS-232C parameters

(1)Press the F2 (RS-232C) key to set it ON. The parameter display now appears.

BAUD RATE: 300, 600, 1200, 2400, 4800, 9600 bps

DATA LENGTH: 7 or 8 bits

START BIT:

1 bit, fixed

STOP BIT:

2 or 1 bit

PARITY:

None, odd or even

(2)Press the center cursor key. The input area now blinks.

(3)Press the cursor keys to select the input area.

The cursor moves on a block by block basis when the F key and cursor key are pressed together.

BAUD RATE:

4800

(4) Press the center cursor key to set the parameter.

BAUD RATE:

9600

(5) Press the ENT key to enter the setting.

Setting the V/A control parameters

The AV control parameter is fixed at the baud rate of 1200 bps.