AUTO OFF error messages

Message

Error description

On-screen display

CPU TAPE HANDLE

The CPU is not working properly due to an error

SYSCON ERROR

TROUBLE

in the interrupt processing, etc.

 

 

 

 

CPU (SERVO SYS) COMM.

A problem has occurred in communication

SERVO ERROR

TROUBLE

between the servo microcomputer and system

 

 

control microcomputer.

 

 

 

 

CASSETTE PHOTO

A problem with the LED has been detected.

MECHA ERROR

SENSOR TROUBLE

 

 

DETECTION SWITCH FAIL

There is a problem with the cassette’s 3-stage

MECHA ERROR

(A)

switch (A) (on the cylinder side).

 

 

 

 

DETECTION SWITCH FAIL

There is a problem with the cassette’s 3-stage

MECHA ERROR

(B)

switch (B) (middle position).

 

 

 

 

DETECTION SWITCH FAIL

There is a problem with the cassette’s 3-stage

MECHA ERROR

(C)

switch (C) (on the cassette insertion slot side).

 

ROTATE-RANGE OVER

A problem with the cylinder’s rotation has been

SERVO ERROR

 

detected.

 

 

 

 

CAPSTAN NOT ROTATE

A problem with the capstan’s rotation has been

SERVO ERROR

 

detected.

 

 

 

 

TAPE TENSION ERROR

A tape tension error has been detected. (Pinch

SERVO ERROR

 

roller ON status) Check the tape transport

 

 

system.

 

TAPE TENSION OVER-

A tape tension error has been detected. (Reel

SERVO ERROR

RANGE IN SHTL

drive status with pinch roller OFF) Check the

 

 

tape transport system.

 

 

 

 

REEL DIRECTION

A discrepancy in the rotational directions of the

SERVO ERROR

UNMUTCH

supply and take-up reels has been detected.

 

 

Check the tape transport system.

 

 

 

 

WIND-UP REEL NOT

Defective rotation of the take-up reel has been

SERVO ERROR

ROTATE

detected. (During capstan drive) Check the tape

 

 

transport system.

 

NO S-REEL FG PULSE

Trouble with the rotation of the supply reel has

SERVO ERROR

 

been detected.

 

 

 

 

NO T-REEL FG PULSE

Trouble with the rotation of the take-up reel has

SERVO ERROR

 

been detected.

 

 

 

 

CASSETTE UNLOAD FAIL

A problem with the cassette “up” operation has

MECHA ERROR

 

occurred. Check the tape transport system.

 

SUB UNLACING FAIL

A problem with the sub-unloading operation has

MECHA ERROR

 

occurred. Check the tape transport system.

 

 

 

 

MAIN UNLACING FAIL

A problem with the main unloading operation

MECHA ERROR

 

has occurred. Check the tape transport system.

 

 

 

 

DEW

The formation of condensation has been

MECHA ERROR

 

detected. Refrain from inserting a cassette since

 

 

this condition may cause the tape to adhere to

 

 

the inside parts, etc., thereby damaging it.

 

– 187 –

Page 187
Image 187
Panasonic AJ-HD2000 CPU Tape Handle, Syscon Error, Trouble, CPU Servo SYS Comm, Servo Error, Cassette Photo, Mecha Error