SYSTEM error messages

Message

Error description

On-screen display

AV NOT RESPONDING

The AV microcomputer is not working properly.

SYSTEM ERROR

 

The reference signals from the S5 printed circuit

 

 

board may not be the prescribed ones or some

 

 

similar kind of problem is to blame.

 

 

 

 

SYSCON NOT

A problem has occurred in communication

SYSTEM ERROR

RESPONDING

between the system control microcomputer and

 

 

front microcomputer.

 

 

 

 

S2 BOARD NOT

The S2 printed circuit board has been removed.

SYSTEM ERROR

RESPONDING

 

 

S3 BOARD NOT

The S3 printed circuit board has been removed.

SYSTEM ERROR

RESPONDING

 

 

 

 

 

S4 BOARD NOT

The circuitry on the S4 PCB is not operating

SYSTEM ERROR

RESPONDING

properly.

 

 

 

 

S5 BOARD NOT

The circuitry on the S5 PCB is not operating

SYSTEM ERROR

RESPONDING

properly.

 

L1 BOARD NOT

The circuitry on the L1 PCB is not operating

SYSTEM ERROR

RESPONDING

properly.

 

 

 

 

L2 BOARD NOT

The circuitry on the L2 PCB is not operating

SYSTEM ERROR

RESPONDING

properly.

 

 

 

 

CASSETTE LOAD FAIL

A problem has occurred during the cassette

MECHA ERROR

 

“down” operation.

 

SUB LACING FAIL

A problem was detected during the sub-loading

MECHA ERROR

 

operation, and the cassette was ejected. Check

 

 

the tape transport system.

 

 

 

 

MAIN LACING FAIL

A problem was detected during the main loading

MECHA ERROR

 

operation, and the cassette was ejected. Check

 

 

the tape transport system.

 

 

 

 

HUB POSITION

The reel hub position does not match the

MECHA ERROR

 

cassette size. The cassette was ejected as a

 

 

result.

 

– 189 –

Page 189
Image 189
Panasonic AJ-HD3700A AV not Responding, System Error, Syscon not, S2 Board not, Responding S3 Board not, S5 Board not