Connection of the external switch
It is possible to draw 1.5 A current from the DC OUT connector of the unit.
Recording start/stop can be controlled by connecting an external switch to this connector.
Since a tally lamp can be used by connecting an LED to this connector, it is useful for shooting video when fixing the camera on a crane.
Preparation
DC OUT connector
Connector at the cable side
41
3 2
LED
Resistance
Max. 50 mA | Recording start/stop |
1:GND
2:TALLY OUT
Open collector output on the unit side.
TALLY ON: | Low impedance |
TALLY OFF: | High impedance |
3:Recording start/stop switch
This is connected in parallel to the REC START/STOP button on the unit or the VTR button on the lens.
4:+12 V
Preparation: Connection of the external switch 119