| Items/ |
| Adjustable |
| Remarks | |||||
Data Saved |
|
| Range |
| ||||||
|
|
|
| |||||||
ENDURA10 |
|
|
|
| Enable selection under BATTERY | |||||
|
|
|
|
|
| • | SELECT. | |||
|
|
|
|
|
|
|
|
| : | Enable selection. |
|
|
|
|
|
|
|
|
| • : | Disable selection. |
|
|
|
|
| AUTO | Select auto or manual to set the NEAR | ||||
|
|
|
|
| MANUAL | END voltage. | ||||
|
|
|
|
|
|
|
|
| AUTO: Set voltage automatically. | |
|
|
|
|
|
|
|
|
| MANUAL: | |
|
|
|
|
|
|
|
|
|
| Set voltage manually. |
|
|
|
|
| 11.0 |
| When “MANUAL” is selected in the | |||
|
|
|
|
| : |
|
| menu above, set the NEAR END voltage | ||
|
|
|
|
| 13.2 |
| in 0.1 V steps. | |||
|
|
|
|
|
| : |
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| 15.0 |
|
|
| ||
– | C | U | F | – |
|
|
|
|
|
|
|
|
|
| Enable selection under BATTERY | ||||||
|
|
|
|
|
| • | SELECT. | |||
|
|
|
|
|
|
|
|
| : | Enable selection. |
|
|
|
|
|
|
|
|
| • : | Disable selection. |
|
|
|
|
| AUTO | Select auto or manual to set the NEAR | ||||
|
|
|
|
| MANUAL | END voltage. | ||||
|
|
|
|
|
|
|
|
| AUTO: Set voltage automatically. | |
|
|
|
|
|
|
|
|
| MANUAL: | |
|
|
|
|
|
|
|
|
|
| Set voltage manually. |
|
|
|
|
| 11.0 |
| When “MANUAL” is selected in the | |||
|
|
|
|
| : |
|
| menu above, set the NEAR END voltage | ||
|
|
|
|
| 13.2 |
| in 0.1 V steps. | |||
|
|
|
|
|
| : |
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| 15.0 |
|
|
| ||
– | C | U | F | – |
|
|
|
|
|
|
PAG L95 |
|
|
|
| Enable selection under BATTERY | |||||
|
|
|
|
|
| • | SELECT. | |||
|
|
|
|
|
|
|
|
| : | Enable selection. |
|
|
|
|
|
|
|
|
| • : | Disable selection. |
|
|
|
|
| AUTO | Select auto or manual to set the NEAR | ||||
|
|
|
|
| MANUAL | END voltage. | ||||
|
|
|
|
|
|
|
|
| AUTO: Set voltage automatically. | |
|
|
|
|
|
|
|
|
| MANUAL: | |
|
|
|
|
|
|
|
|
|
| Set voltage manually. |
|
|
|
|
| 11.0 |
| When “MANUAL” is selected in the | |||
|
|
|
|
| : |
|
| menu above, set the NEAR END voltage | ||
|
|
|
|
| 13.5 |
| in 0.1 V steps. | |||
|
|
|
|
|
| : |
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| 15.0 |
|
|
| ||
– | C | U | F | – |
|
|
|
|
|
|
|
|
|
| Enable selection under BATTERY | ||||||
|
|
|
|
|
| • | SELECT. | |||
|
|
|
|
|
|
|
|
| : | Enable selection. |
|
|
|
|
|
|
|
|
| • : | Disable selection. |
|
|
|
|
| AUTO | Select auto or manual to set the NEAR | ||||
|
|
|
|
| MANUAL | END voltage. | ||||
|
|
|
|
|
|
|
|
| AUTO: Set voltage automatically. | |
|
|
|
|
|
|
|
|
| MANUAL: | |
|
|
|
|
|
|
|
|
|
| Set voltage manually. |
|
|
|
|
| 11.0 |
| When “MANUAL” is selected in the | |||
|
|
|
|
| : |
|
| menu above, set the NEAR END voltage | ||
|
|
|
|
| 13.5 |
| in 0.1 V steps. | |||
|
|
|
|
| : |
|
| |||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| 15.0 |
|
|
| ||
– | C | U | F | – |
|
|
|
|
|
|
BATTERY SETTING2
| Items/ |
| Adjustable |
| Remarks |
|
| |||||
Data Saved |
|
| Range |
|
|
| ||||||
|
|
|
|
|
| |||||||
NiCd14 |
|
|
|
| Enable selection under BATTERY |
|
| |||||
|
|
|
|
|
| • | SELECT. |
|
| |||
|
|
|
|
|
|
|
|
| : | Enable selection. |
|
|
|
|
|
|
|
|
|
|
| • : | Disable selection. |
|
|
| NEAR END | 11.0 |
| Set the NEAR END voltage in 0.1 V |
|
| ||||||
|
|
|
|
| : |
|
| steps. |
|
|
| |
|
|
|
|
| 13.8 |
|
|
|
| |||
|
|
|
|
| : |
|
|
|
|
|
| |
|
|
|
|
| 15.0 |
|
|
|
| |||
| END | 11.0 |
| Set the END voltage in 0.1 V steps. |
|
| ||||||
|
|
|
|
| : |
|
|
|
|
|
| |
|
|
|
|
| 13.4 |
|
|
|
| |||
|
|
|
|
|
| : |
|
|
|
|
|
|
|
|
|
|
| 15.0 |
|
|
|
| |||
– | C | U | F | – |
|
|
|
|
|
|
|
|
TYPE A |
|
|
|
| Enable selection under BATTERY |
|
| |||||
|
|
|
|
|
| • | SELECT. |
|
| |||
|
|
|
|
|
|
|
|
| : | Enable selection. |
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| • : | Disable selection. |
|
|
|
|
|
|
|
|
|
|
|
| |||
| FULL | 12.0 | Set the voltage to display the FULL |
| Menu | |||||||
|
|
|
|
| : |
|
| indication in 0.1 V steps. |
| |||
|
|
|
|
| 15.1 |
|
|
|
| |||
|
|
|
|
| : |
|
|
|
|
|
| |
|
|
|
|
| 17.0 |
|
|
|
| |||
| NEAR END | 11.0 |
| Set the NEAR END voltage in 0.1 V |
|
| ||||||
|
|
|
|
| : |
|
| steps. |
|
|
| |
|
|
|
|
| 13.6 |
|
|
|
| |||
|
|
|
|
| : |
|
|
|
|
|
| |
|
|
|
|
| 15.0 |
|
|
|
| |||
| END | 11.0 |
| Set the END voltage in 0.1 V steps. |
|
| ||||||
|
|
|
|
| : |
|
|
|
|
|
| |
|
|
|
|
| 12.9 |
|
|
|
| |||
|
|
|
|
| : |
|
|
|
|
|
| |
|
|
|
|
| 15.0 |
|
|
|
| |||
– | C | U | F | – |
|
|
|
|
|
|
|
|
TYPE B |
|
|
|
| Enable selection under BATTERY |
|
| |||||
|
|
|
|
|
| • | SELECT. |
|
| |||
|
|
|
|
|
|
|
|
| : | Enable selection. |
|
|
|
|
|
|
|
|
|
|
| • : | Disable selection. |
|
|
| FULL | 12.0 | Set the voltage to display the FULL |
|
| |||||||
|
|
|
|
| : |
|
| indication in 0.1 V steps. |
|
| ||
|
|
|
|
| 15.5 |
|
|
|
| |||
|
|
|
|
| : |
|
|
|
|
|
| |
|
|
|
|
| 17.0 |
|
|
|
| |||
| NEAR END | 11.0 |
| Set the NEAR END voltage in 0.1 V |
|
| ||||||
|
|
|
|
| : |
|
| steps. |
|
|
| |
|
|
|
|
| 13.5 |
|
|
|
| |||
|
|
|
|
| : |
|
|
|
|
|
| |
|
|
|
|
| 15.0 |
|
|
|
| |||
| END | 11.0 |
| Set the END voltage in 0.1 V steps. |
|
| ||||||
|
|
|
|
| : |
|
|
|
|
|
| |
|
|
|
|
| 13.1 |
|
|
|
| |||
|
|
|
|
|
| : |
|
|
|
|
|
|
|
|
|
|
| 15.0 |
|
|
|
| |||
– | C | U | F | – |
|
|
|
|
|
|
|
|
The remaining battery level is indicated in percentage when a battery with this function is installed on the unit.