Items/

Adjustable

Remarks

Data Saved

Range

 

USR SW F.RATE

(720-59.94P,

When the FRATE function has been

 

 

 

 

 

720-60P)

assigned to a user button, the starting

 

 

 

 

 

1FRAME

frame rate under VFR operation is set.

 

 

 

 

 

:

 

 

 

 

 

This setting is only displayed when 720P

 

 

 

 

 

24FRAME

 

 

 

 

 

has been selected.

 

 

 

 

 

:

 

 

 

 

 

60FRAME

When the mode has been changed

 

 

 

 

 

(720-50P)

using other settings and the frame rate

 

 

 

 

 

1FRAME

value set here exceeds the maximum

 

 

 

 

 

:

frame rate allowed by the set mode, the

 

 

 

 

 

25FRAME

 

 

 

 

 

maximum frame rate is changed to the

 

 

 

 

 

:

 

 

 

 

 

50FRAME

maximum frame rate of the set mode.

S

C

U

F

R

 

 

SCAN REVERSE

ON

This setting is for correcting an image

 

 

 

 

 

OFF

which has been inverted by a film-use

 

 

 

 

 

 

lens or anamorphic lens attached to the

 

 

 

 

 

 

unit.

S

C

U

F

R

 

 

PC MODE SEL

USB HOST

This is for setting the operations mode of

 

 

 

 

 

USB DEV.

this unit when PC MODE is set to “ON”

 

 

 

 

 

 

and an external device is connected to

 

 

 

 

 

 

the USB connector.

 

 

 

 

 

 

USB HOST:

 

 

 

 

 

 

Allows data transfer from the unit

 

 

 

 

 

 

to the USB-connected device.

 

 

 

 

 

 

USB DEV.:

 

 

 

 

 

 

Allows data transfer from the

 

 

 

 

 

 

USB-connected device to the

 

 

 

 

 

 

unit.

 

 

 

 

 

 

Note

 

 

 

 

 

 

When the PC MODE menu option is set

 

 

 

 

 

 

to “ON”, no change can be made to this

 

 

 

 

 

 

option.

F

 

 

PC MODE

ON

Used to enable or disable the mode that

 

 

 

 

 

OFF

allows the unit to be connected to a PC

 

 

 

 

 

 

or an external hard disk drive via

 

 

 

 

 

 

USB 2.0.

 

 

 

 

 

 

ON: Sets the unit to the mode

 

 

 

 

 

 

selected through the PC MODE

 

 

 

 

 

 

SELECT menu option.

 

 

 

 

 

 

OFF: Disables the PC MODE for

 

 

 

 

 

 

normal operation.

 

 

 

 

 

 

Note

 

 

 

 

 

 

Once the power is turned off, the option

 

 

 

 

 

 

is always set to “OFF” when the power is

 

 

 

 

 

 

turned on next time.

F

 

 

OPTION MODE

 

Items/

Adjustable

 

Remarks

Data Saved

Range

 

 

 

REC TALLY

RED

Select the method for displaying the

 

 

 

 

 

GREEN

recording status of unit when controlling

 

 

 

 

 

CHAR

an external VTR by setting 1394

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL items to “BOTH”.

 

 

 

 

 

 

Select the 1394 CONTROL item on the

 

 

 

 

 

 

<1394 SETTING> screen on the

 

 

 

 

 

 

SYSTEM SETTING page.

 

 

 

 

 

 

RED:

The red tally lamp lights up.

 

 

 

 

 

 

GREEN: The green tally lamp lights up.

 

 

 

 

 

 

CHAR: The viewfinder displays “REC” in

 

 

 

 

 

 

 

characters.

C

U

F

 

 

 

ACCESS LED

OFF

Specify whether or not to enable the P2

 

 

 

 

 

SLOT SIDE

card access LEDs.

 

 

 

 

 

LCD SIDE

OFF:

Disables both LEDs above the

 

 

 

 

 

BOTH

 

 

 

 

 

 

slots and on the side panel.

 

 

 

 

 

 

 

 

 

 

 

 

 

SLOT SIDE:

 

 

 

 

 

 

 

Enables the LED above the slots

 

 

 

 

 

 

 

and disables the LED on the side

 

 

 

 

 

 

 

panel.

 

 

 

 

 

 

LCD SIDE:

 

 

 

 

 

 

 

Enables the LED on the side

 

 

 

 

 

 

 

panel and disables the LED

 

 

 

 

 

 

 

above the slots.

 

 

 

 

 

 

BOTH: Enables both LEDs above the

 

 

 

 

 

 

 

slots and on the side panel.

C

U

F

 

 

 

P.OFF GPS

HOLD

Select whether or not to hold the UMID

DATA

CLEAR

GPS position information while the

 

 

 

 

 

 

power is turned off, thereby keeping this

 

 

 

 

 

 

information as status data holding the

 

 

 

 

 

 

previous value until the power is turned

 

 

 

 

 

 

on again, which enables a new

 

 

 

 

 

 

measurement to start.

 

 

 

 

 

 

HOLD: Hold and save the data.

 

 

 

 

 

 

CLEAR: Clear the data when the power is

 

 

 

 

 

 

 

turned off, and save zero (No-

 

 

 

 

 

 

 

Info) from the next power-on

 

 

 

 

 

 

 

until a new measurement is

 

 

 

 

 

 

 

completed.

C

U

F

 

 

 

SDI METADATA

ON

Used to specify whether or not to output

 

 

 

 

 

OFF

metadata (UMID) to HD SDI.

C

U

F

 

 

 

SAVE SW (AUD

ON

Select whether or not to forcibly disable

OUT)

OFF

the audio output when the SAVE ON/

 

 

 

 

 

 

OFF switch is set to [ON].

 

 

 

 

 

 

ON:

Disable audio output.

 

 

 

 

 

 

OFF:

Enable audio output.

C

U

F

 

 

 

SAVE SW (LCD)

ON

Select whether or not to automatically

 

 

 

 

 

OFF

turn off the LCD monitor when the SAVE

 

 

 

 

 

 

ON/OFF switch is set to [ON].

 

 

 

 

 

 

ON:

Turn off LCD monitor.

 

 

 

 

 

 

OFF:

Do not turn off LCD monitor.

C

U

F

 

 

 

COMPRESSION

NORMAL

Select a compression mode for the 720P

MODE

DARK

mode (Only for recording DVCPRO HD

 

 

 

 

 

 

for 720-59.94P, 720-60P and 720-50P).

 

 

 

 

 

 

NORMAL:

 

 

 

 

 

 

 

The normal shooting mode is

 

 

 

 

 

 

 

selected.

 

 

 

 

 

 

DARK: Compressed video distortion

 

 

 

 

 

 

 

that occurs in dark areas is

 

 

 

 

 

 

 

lowered, which may increase

 

 

 

 

 

 

 

distortion in other areas.

C

U

F

 

 

 

166 Menu: Menu Description Tables