Warning System

Warning Description Tables

If a problem is detected immediately after the power is turned on, or during operation, this will be indicated by the WARNING lamp, lamps inside the viewfinder and a warning tone.

Note

The WARNING lamp has the highest priority, followed by the tally lamp, and then the warning tone. When multiple errors occur simultaneously a higher priority indication will be triggered. The [WIRELESS-RF], however, may not be indicated, depending on the menu setting.

1. System Errors

Display window

The error code lights up.

indication

 

 

 

WARNING lamp

Blinks 4 times per second.

 

 

Tally lamp

Blinks 4 times per second.

 

 

Viewfinder

The “SYSTEM ERROR” indication and

the error code light up.

 

 

 

Warning tone

Beeps continuously.

 

 

Warning description

An error in the reference signal or the

communication.

 

 

 

Recording/playback

The operation stops.

operation

 

Countermeasures

Please confirm [Error Codes] (page 158)

and consult your distributor.

 

 

 

2.Card removal error

Display window

Error code “E-30” blinks.

indication

 

 

 

WARNING lamp

Blinks 4 times per second.

 

 

Tally lamp

Blinks 4 times per second.

 

 

Viewfinder

The “TURN POWER OFF” indicator lights

up.

 

 

 

Warning tone

Continues to beep.

 

 

Warning description

The P2 card being accessed has been

removed, resulting in an error in the

 

internal memory of the unit.

 

 

Recording/playback

Cannot be performed.

operation

 

Countermeasures

Turn off the power to the unit. If there is

an error in a clip on the removed P2 card,

 

repair the clip.

 

 

3. Battery Empty

Display window

All 7 bar indicators for battery remaining

indication

capacity start blinking.

 

 

WARNING lamp

Lights up.

 

 

Tally lamp

Blinks once per second.

 

 

Viewfinder

The BATT LED lights up.

 

 

Warning tone

Beeps continuously.

 

 

Warning description

The battery has run out.

 

 

Recording/playback

The operation stops.

operation

 

Countermeasures

Replace the battery.

 

 

4.P2 Card Fully Recorded

Display window

All 7 bar indicators for remaining MEDIA

 

 

indication

capacity start blinking.

 

 

 

 

 

 

 

WARNING lamp

This lamp will illuminate continuously until

 

Maintenance

an operation is made after recording.

 

 

 

 

 

 

Tally lamp

This lamp will flash 4 times every second

 

 

 

until an operation is made after recording.

 

 

 

 

 

 

 

 

 

Viewfinder

The “END” indicator blinks.

 

 

When a write protected P2 card has been

 

 

 

inserted, the “WP” indicator lights up.

 

and

 

 

 

Warning tone

This tone will sound continuously until an

 

operation is made after recording.

 

Inspections

 

 

 

 

 

Recording/playback

The recording stops.

 

Warning description

The P2 cards are recorded to maximum

 

 

 

capacity.

 

 

operation

 

 

 

 

 

 

 

Countermeasures

Delete the clips in the P2 card or insert a

 

 

new P2 card.

 

 

 

 

 

 

 

 

 

5.Image Sequence Error (24P, 30P, 25P)

Display window

“E-40” appears in the time code display

indication

field.

 

 

WARNING lamp

Blinks 4 times per second.

 

 

Tally lamp

Blinks 4 times per second while recording

continues.

 

 

 

Viewfinder

The “REC WARNING” indicator lights up.

 

 

Warning tone

Beeps 4 times per second while recording

continues.

 

 

 

Warning description

There are abnormal conditions in the

image sequence of the 24P, 30P, or 25P

 

mode.

 

 

Recording/playback

Images can be recorded and played

back, but some frames may be dropped

operation

or the sequences of TC and UB may shift.

 

 

 

 

Confirm the recording/playback operation

Countermeasures

after turning off the power supply once

and then turning it on again. If the error is

 

not corrected after executing this

 

procedure, contact the dealer.

 

 

Maintenance and Inspections: Warning System 155