MAIN OPERATION
The ____ in the Adjustable Range column indicates the preset mode.
BATTERY/P2CARD
| Items/ | Adjustable | Remarks | ||||
Data Saved | Range | ||||||
| |||||||
BATTERY | PROPAC14 | Select the battery to use. Remaining | |||||
SELECT | TRIMPAC14 | capacity detection is also performed | |||||
|
|
|
|
| HYTRON50 | according to the selected battery. | |
|
|
|
|
| HYTRON140 | ||
|
|
|
|
| The variable range is changed by the | ||
|
|
|
|
| DIONIC90 | ||
|
|
|
|
| item settings selected on the [BATTERY | ||
|
|
|
|
| DIONIC160 | ||
|
|
|
|
| |||
|
|
|
|
| ENDURA7 | SETTING2] (page 191) menus. | |
|
|
|
|
| ENDURA10 | The initial value for “TYPE A” is set to | |
|
|
|
|
| |||
|
|
|
|
| “DIONIC90” while the same for “TYPE B” | ||
|
|
|
|
| PAG L95 | ||
|
|
|
|
| is set to “HYTRON140”. | ||
|
|
|
|
| |||
|
|
|
|
| NiCd14 | When | |
|
|
|
|
| TYPE A | made of Sony, is used, set this to “BP- | |
|
|
|
|
| TYPE B | L65/95”. | |
– | C | U | F | – |
|
| |
EXT DC IN | AC_ADPT | Set the remaining capacity detection | |||||
SELECT | PROPAC14 | type when a battery is connected to the | |||||
|
|
|
|
| TRIMPAC14 | DC IN connector. Remaining capacity | |
|
|
|
|
| HYTRON50 | ||
|
|
|
|
| detection is also performed according to | ||
|
|
|
|
| HYTRON140 | ||
|
|
|
|
| the selected battery type. | ||
|
|
|
|
| DIONIC90 | ||
|
|
|
|
| DIONIC160 | The variable range is changed by the | |
|
|
|
|
| item settings selected on the [BATTERY | ||
|
|
|
|
| ENDURA7 | ||
|
|
|
|
| ENDURA10 | SETTING2] (page 191) menus. | |
|
|
|
|
| |||
|
|
|
|
| Analog voltage is displayed on the | ||
|
|
|
|
| PAG L95 | ||
|
|
|
|
| viewfinder screen. | ||
|
|
|
|
| NiCd14 | When | |
|
|
|
|
| TYPE A | made of Sony, is used, set this to “BP- | |
|
|
|
|
| TYPE B | L65/95”. | |
|
|
|
|
|
| ||
– | C | U | F | – |
|
| |
BATT NEAR | ON | Select whether or not to set the alarm to | |||||
END ALARM | OFF | beep when the battery level is low. | |||||
– | C | U | F | – |
|
| |
BATT NEAR | ON | If set to “ON”, the warning tone and | |||||
END CANCEL | OFF | indication can be canceled by pressing | |||||
|
|
|
|
|
| the MODE CHECK button when BATT | |
|
|
|
|
|
| NEAR END ALARM is triggered. | |
– | C | U | F | – |
|
| |
BATT END | ON | Select whether or not to set the alarm to | |||||
ALARM | OFF | beep when the battery is empty. | |||||
– | C | U | F | – |
|
| |
BATT REMAIN | 70% | Set the display of the remaining battery | |||||
FULL | 100% | level indicator bar in the display window | |||||
|
|
|
|
|
| when a battery with this function is used. | |
|
|
|
|
|
| 70%: Indicate FULL at 70% capacity. | |
|
|
|
|
|
| 100%: Indicate FULL at 100% capacity. | |
– | C | U | F | – |
|
|
| Items/ | Adjustable | Remarks |
|
| |||
Data Saved | Range |
|
| |||||
|
|
| ||||||
CARD NEAR | ON | Select whether or not to set the alarm to |
|
| ||||
END ALARM | OFF | beep when the space remaining on the |
|
| ||||
|
|
|
|
|
| P2 card is small. |
|
|
– | C | U | F | – |
|
|
|
|
CARD NEAR | 2min | Set the time at which to indicate that |
|
| ||||
END TIME | 3min | there is little space remaining on the P2 |
|
| ||||
|
|
|
|
|
| card. |
|
|
– | C | U | F | – |
|
|
|
|
CARD END | ON | Select whether or not to set the alarm to |
|
| ||||
ALARM | OFF | beep when the P2 card is full. |
|
| ||||
– | C | U | F | – |
|
|
|
|
|
|
|
| |||||
CARD REMAIN/ | 3min/ | Set the length of time for one segment |
|
| ||||
| ||||||||
|
|
|
|
| 5min/ | () of the P2 card’s remaining capacity |
| Menu |
|
|
|
|
|
| indicator bars. |
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 3min/: One segment represents |
|
|
|
|
|
|
|
| 3 minutes. |
|
|
|
|
|
|
|
| 5min/: One segment represents |
|
|
|
|
|
|
|
| 5 minutes. |
|
|
– | C | U | F | – |
|
|
|
|
Menu: Menu Description Tables 189