6.Recording Error

Display window

“00:00:00:11” appears in the time code

display field. Even after recording is

indication

stopped, this display continues to blink

 

until the next operation is performed.

 

 

WARNING lamp

Blinks 4 times per second while recording

continues.

 

 

 

Tally lamp

Blinks 4 times per second while recording

continues.

 

 

 

Viewfinder

The “REC WARNING” indicator lights up.

 

 

Warning tone

Beeps 4 times per second while recording

continues.

 

 

 

 

This indicates a failure either in the P2

 

card recording or the recording circuit.

Warning description

This is displayed when attempting to

record clips where the total quantity

 

 

exceeds the upper limit (1000 pieces) for

 

a single P2 card.

 

 

Recording/playback

The recording may stop or continue.

operation

 

 

Confirm the recording/playback operation

Countermeasures

after turning off the power supply once

and then turning it on again.

 

If the recording cannot be performed

 

normally, change the P2 card.

 

 

7.Low Wireless Signal Reception

Display window

No display.

indication

 

 

 

WARNING lamp

Blinks 4 times per second (during pause

and recording).

 

 

 

Tally lamp

Blinks 4 times per second while recording

continues.

 

 

 

Viewfinder

The “WIRELESS-RF” indicator lights up

while recording continues.

 

 

 

Warning tone

Beeps 4 times per second while recording

continues.

 

 

 

Warning description

This error indicates poor wireless audio

reception conditions.

 

 

 

Recording/playback

Continues to operate without receiving

operation

the wireless microphone signal.

Countermeasures

Check the microphone power supply and

the reception status of the wireless

 

receiver.

 

 

8. 1394 Error

Display window

The “1394 E-92” indicator in the display

indication

window blinks.

 

 

WARNING lamp

Blinks 4 times per second while recording

continues.

 

 

 

Tally lamp

Blinks 4 times per second while recording

continues.

 

 

 

Viewfinder

“1394 INITIAL ERROR” indicator lights up

(during pause and recording).

 

 

 

Warning tone

Beeps 4 times per second while recording

continues.

 

 

 

Warning description

This indicates a failure of the DVCPRO

connector.

 

 

 

Recording/playback

Signals cannot be controlled or supplied

to the device connected to the DVCPRO

operation

connector. However, recording and

 

playback can be performed on the unit.

 

 

 

Check the connection between the

 

IEEE1394 cable and the DVCPRO

Countermeasures

connector, settings of any external device

and menus, and the turn on the power

 

again.

 

If the warning indication is still

 

illuminated, consult your distributor.

 

 

9.Battery Nearly Empty

Display window

One of the bars in the battery remaining

indication

indicator starts blinking.

 

 

WARNING lamp

Blinks once per second.

 

 

Tally lamp

Blinks once per second.

 

 

Viewfinder

The “BATT” LED blinks.

 

 

Warning tone

Beeps 4 times per second.

 

 

Warning description

The battery is about to run out.

 

 

Recording/playback

Continues to operate.

operation

 

Countermeasures

Replace the battery as required.

 

 

10. P2 Card Nearly Full

Display window

One of the bars for remaining MEDIA

indication

capacity starts blinking.

 

 

WARNING lamp

Blinks once per second while recording

continues.

 

 

 

Tally lamp

Blinks once per second while recording

continues.

 

 

 

Viewfinder

The P2 card remaining capacity indicator

blinks.

 

 

 

Warning tone

Beeps once per second while recording

continues.

 

 

 

Warning description

The total remaining capacity of all the P2

cards is 2 minutes or less.

 

 

 

Recording/playback

Continues to operate.

operation

 

Countermeasures

Replace the cards. If there is an empty

card slot, insert a new card.

 

 

 

156 Maintenance and Inspections: Warning System