3.1.8Resetting this Product to Factory Default
All settings are reset to factory default directly after the Execute button is clicked.
1.Click [Reset to Factory Default] on the Maintenance page.
2.Click [Execute].
•The indicator blinks orange, and then turns off for 10 seconds.
•All settings (user name, password, IP address, subnet mask etc.) are reset to factory default.
•If this product is reset to factory default, the network connection mode changes to [Automatic Setup]. Reconfigure this product seeing the Getting Started.
Notes
•Do not turn off this product during the reset operation.
•The internal clock will not be reset, but the time format will return to AM/ PM mode (see page 64). Set it again.
•See page
•Pressing the FACTORY DEFAULT RESET button resets this product to the factory default (see page 145).
•All buffered images and alarm logs on the internal memory are deleted when resetting this product to factory default. The buffered images on the SD memory card are not deleted.
•The reset operation takes about 1 minute.
•If this product is restarted, all alarm logs are deleted.