7 Configure the basic settings of the camera [Basic]
| Operation status |
|
|
| Indicator status |
| |||
|
|
|
|
|
|
|
|
|
|
| During the initialization |
|
|
| Blinks orange → Lights off |
| |||
|
|
|
|
|
|
|
|
|
|
| Port forwarding error caused by the UPnP function |
|
| Blinks orange (in 2 seconds |
| ||||
|
|
|
|
| intervals (on for 1 second / off |
| |||
|
|
|
|
| for 1 second)) |
| |||
|
|
|
|
|
|
|
|
|
|
| Trouble happening on the camera |
|
|
| Blinks red |
| |||
|
|
|
|
|
|
|
|
|
|
| When there is a body heat sensor detection | VT164W |
|
| Lights orange (for 1 second) |
| |||
| VT164 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| During privacy mode |
|
|
| Lights red |
| |||
|
|
|
|
|
|
|
|
|
|
• WIRELESS indicator (Red/Orange/Green) | VT164W | VP104W : The WIRELESS indicator will light or | |||||||
| blink as follows depending on the wireless status. |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| ||
| Operation status |
|
|
| Indicator status |
| |||
|
|
|
|
|
|
|
|
|
|
| WPS is not configured |
|
|
| Lights off |
| |||
|
|
|
|
|
|
|
|
|
|
| WPS is starting up |
|
|
| Blinks orange |
| |||
|
|
|
|
|
|
|
|
|
|
| WPS settings succeeded (WPS defined) |
|
|
| Lights green |
| |||
|
|
|
|
|
|
|
|
|
|
| WPS settings failed |
|
|
| Blinks red for about 10 |
| |||
|
|
|
|
| seconds → Lights off |
| |||
|
|
|
|
|
|
|
|
|
|
[Alarm status update mode]
Select an interval of the camera status notification from the following.
When the status of the camera changes, the alarm occurrence indication button, the [AUX] button will be displayed to notify of the camera status.
•Polling(30s): Updates the status each 30 seconds and provide notification of the camera status.
•Real time: Provide notification of the camera status when the status has changed.
•Default: Polling(30s)
Note
•Depending on the network environment, notification may not be provided in real time.
[Alarm status reception port]
When selecting “Real time” for “Alarm status update mode”, designate a port number to which the status change notification is to be sent.
•Available port number: 1 - 65535
•Default: 31004
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 995, 10669, 10670
[Automatic installation of viewer software]
Determine whether or not to install the viewer software from this camera.
•On: Installs the viewer software from the camera automatically.
•Off: The viewer software cannot be installed from the camera.
•Default: On