11 Configure the alarm settings [Alarm]

11 Configure the alarm settings [Alarm]

The settings relating to alarm occurrences such as settings for the alarm action at an alarm occurrence, the VMD area settings, and the alarm occurrence notification can be configured on this page.

The “Alarm” page has 3 tabs; the [Alarm] tab, the [VMD area] tab and the [Notification] tab.

11.1Configure the settings relating to the alarm action [Alarm]

Click the [Alarm] tab on the “Alarm” page. (page 34, page 35)

The settings relating to the alarm can be configured in this section. Refer to page 80 and page 82 for further information about the settings relating to the alarm images and the alarm output terminal.

Alarm

[Terminal 1] VT164W

VT164

Determine how to use terminal 1.

Off: Not used.

Alarm input: Receives alarms.

Close: An alarm is detected when the terminal status is changed to “On”.

Open: An alarm is detected when the terminal status is changed to “Off”.

Default: Off

[Terminal 2] VT164W

VT164

Determine how to use terminal 2.

Off: Not used.

Alarm input: Receives alarms.

Close: An alarm is detected when the terminal status is changed to “On”.

Open: An alarm is detected when the terminal status is changed to “Off”.

Alarm output: Alarm output will be carried out according to the settings for “Alarm output terminal setup” (page 82).

Default: Off

Operating Instructions