11 Configure the alarm settings [Alarm]

The settings relating to Panasonic alarm protocol can be configured in this section.

Panasonic alarm protocol notification

[Panasonic alarm protocol]

Select “On” or “Off” to determine whether or not to provide notification by Panasonic alarm protocol according to the settings for the “Alarm” and “Diag.” checkboxes of “Destination of notification” below.

When an alarm is detected (“Alarm”)

Default: Off

Note

When “On” is selected for “Alarm”, notification of the alarm occurrence will be provided to the registered destination server addresses in order from “Address 1”.

[Additional alarm area data(VMD)]

Determine whether or not to send notifications for VMD alarm detection area numbers with the Panasonic alarm protocol by selecting On/Off.

Default: Off

[Destination port]

Select a destination port for the Panasonic alarm protocol from the following.

Available range: 1 - 65535

Default: 1818

The following port numbers are unavailable since they are already in use.

20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 995, 10669, 10670

[Retry times]

Select a retry time for the Panasonic alarm protocol.

Operating Instructions

89

Page 89
Image 89
Panasonic BLVT164P Panasonic alarm protocol notification, Additional alarm area dataVMD, Destination port, Retry times