4.2

System Programming

302–305

 

Toll Restriction — Class 2 – 5 Denied Codes

 

 

 

 

 

 

Description

 

These allow the user to specify which numbers are toll-restricted

 

 

for each toll restriction class as follows.

 

 

 

Program [302]: restricts COS number 2.

 

 

 

Program [303]: restricts COS numbers 2 and 3.

 

 

Program [304]: restricts COS numbers 2 – 4.

 

 

Program [305]: restricts COS numbers 2 – 5.

Selection

 

• Code number: 01 – 20

 

 

 

• Toll restriction number: 11 digits

 

Default

 

All codes – Not stored

 

Programming

1. Enter a program address (302 to 305).

 

 

 

Display example: Class-2 Table

Conditions

Feature Reference

2.Press NEXT.

Display: CODE NO?

3.Enter a code number.

Pressing NEXT also can enter code number 01.

Display example: 01: ...........

4.Enter a toll call number.

To delete the current entry, press CLEAR.

To change the current entry, press CLEAR and enter the new number.

5.Press STORE.

6.To program another code, press NEXT or PREV, or SELECT and enter the desired code number.

7.Repeat steps 4 through 6.

8.Press END.

There is a maximum of 20 numbers which can be restricted for each program. Each number must have eleven digits, consisting of 0 – 9, ,

#and x (PAUSE button). The character “x” can be used as a wild card character and is entered by pressing the PAUSE button.

Program [306] “Toll Restriction — Exception Codes” is used to assign exceptions to these numbers. Programs [601]–[603] “TRS – Class of Service (COS) Assignment — Day/Night/Lunch” are used to set the toll restriction value for each extension.