2.12 Starting the Hybrid
Notes
•For safety reasons, follow the procedures as indicated when turning on the Hybrid IP- PBX.
•For safety reasons, do not stretch, bend, or pinch the AC cord and the DC cable of the AC adaptor.
5.Press the Reset Button with a pointed tool. (The RUN indicator will flash.)
6.While the RUN indicator is flashing (within about 10 s), set the System Clear Switch back to the normal position. Depending on the configuration, initialisation takes about 1 min to 3 min. If successfully executed, the RUN indicator will stop flashing and be kept lit.
All data will be cleared, and the Hybrid
The data of the
Notes
•Use the same types of AC adaptor and AC cord that are supplied with the Hybrid IP- PBX only.
LED Indications
Colour | Description | |
|
| |
Green | PBX status indication | |
| • | OFF: Power Off (includes normal reset) |
| • | ON: Power On and running |
| • | Flash (60 times per minute): Power On and starting |
| • | Flash (120 times per minute): Power On and resetting before system |
|
| clear |
|
| |
Red | Alarm detection status indication | |
| • | OFF: Normal |
| • | ON: Alarm (CPU stop, alarm for each card) |
| • | Flash: Alarm (MPR file error in restarting) |
|
|
|
Confirming the Trunk Connection
After initialisation, programme the Hybrid
To confirm, dial [] [3] [7] + trunk number (3 digits) or press
Turning off the Hybrid IP-PBX
For safety reasons, make sure to turn off the power switch before unplugging the Hybrid IP- PBX. To unplug, follow the reverse steps to plug it in.
142 Installation Manual