2.6 Connection of Extensions
2.6.2Parallel Connection of the Extensions
With APT
Any SLT can be connected in parallel with an APT as follows:
To a hybrid extension port
Modular
APT | SLT |
With DPT
Any SLT can be connected in parallel with a DPT as follows:
To a hybrid extension port
Modular
DPT | SLT |
Notes
•In addition to an SLT, an answering machine, a fax machine or a modem (PC) can be connected in parallel with APTs and DPTs.
•If the eXtra Device Port (XDP) mode is enabled through system programming, parallel connection is not possible. Refer to "1.10.9 Parallelled Telephone" and "2.1.1 Extension Port Configuration" in the Feature Guide for further information.
80
Installation Manual