Panasonic KX-TDA30 installation manual Problem, Probable Cause, Solution, Cannot register the PS

Models: KX-TDA30

1 176
Download 176 pages 5.71 Kb
Page 160
Image 160
Cannot register the PS.

4.1 Troubleshooting

 

PROBLEM

 

PROBABLE CAUSE

SOLUTION

 

 

 

 

 

Cannot register the PS.

Wrong Personal

• Register the PIN set to the Hybrid IP-

 

 

 

Identification Number

PBX into the PS.

 

 

 

(PIN) is registered to the

 

 

 

 

PS.

 

 

 

CS is not connected

• Make sure that the cable is connected

 

 

 

properly.

properly with correct pin assignments.

 

 

 

 

Also, make sure that the cable does not

 

 

 

 

make short circuits.

 

 

 

 

• Switch all DIP switches off.

 

 

 

 

• PS becomes out of

CS is not working.

• Make sure that the cable is connected

 

range.

 

 

properly with correct pin assignments.

• Cannot make calls using

 

 

Also, make sure that the cable does not

 

 

make short circuits.

 

the PS.

 

 

 

 

 

 

 

 

 

 

• Switch all DIP switches off.

 

 

Location of CS is not

• Locate the CS properly (refer to "2.7.5

 

 

 

good.

Site Survey Using the KX-TD7590"or

 

 

 

 

"2.8.5 Site Survey" ).

 

 

Access system of the

• Change the access system setting of

 

 

 

PS is not properly set.

the PS to the appropriate system or

 

 

 

 

automatic.

 

 

 

 

• Noise is frequent while

Call handover is not

• Locate the CS properly (refer to "2.7.5

 

using the PS.

 

working.

Site Survey Using the KX-TD7590"or

Conversations

PS is out of CS coverage

"2.8.5 Site Survey" ).

 

 

disconnect while using

 

area.

 

 

the PS.

 

 

 

 

 

 

 

• PS stays out of service

It may take about 20 s

• Wait until the CS starts up.

 

when the CS status is

 

for CS to start up after

 

 

changed from Out of

 

the status has been

 

 

Service to In Service.

 

changed to In Service.

 

 

 

 

 

 

160 Installation Manual

Page 160
Image 160
Panasonic KX-TDA30 installation manual Problem, Probable Cause, Solution, Cannot register the PS