2.6 Connection of Extensions

Connection between KX-T7600 Series DPT (except KX-T7640) and

SLT

In addition to a KX-T7600 series DPT connected in parallel, an SLT can also be connected to KX-T7600 series DPT as follows:

To a hybrid extension port Manual background

4-conductor wiring cord Connect pins "D1" and "D2".

Modular

T-Adaptor

2-conductor wiring cord

Connect pins "T" and "R".

4-conductor wiring cord Connect pins "D1" and "D2".

SLT

Master DPT

Slave DPT

4-conductor wiring cord

TO MAIN UNIT TO TEL / PABX

To a hybrid extension port Manual background To Slave DPT

4-conductor wiring cord

Note

USB Modules must not be connected to DPTs in Digital XDP connection. If a PC is connected to a master DPT via a USB Module, the PC cannot be used for the PC Phone, PC Console, or CTI features. Also, if a USB module is connected to a slave DPT, the DPT cannot work properly.