Indicators

There are two indicators on the front of the projector which give information about the operating condition of the projector. These indicators illuminate or flash to warn you about problems that have occurred inside the projector, so if you notice that one of the indicators is on, turn off the power and check the table below for the cause of the problem.

LAMP indicator

TEMP indicator

Indicator name

TEMP indicator

Indicator display

Problem

 

The internal

 

projector

 

temperature is too

Illuminated (red)

high.

Possible cause

The ventilation holes may be covered.

The ambient temperature in the place of use may be too high.

Remedy

Uncover the ventilation holes.

Set up the projector in a place where the temperature is between 41°F (5°C) and 104°F (40°C) and the humidity is between 10% and 80% (with no condensation).

TEMP

LAMP indicator

LAMP

Flashing (red)

Illuminated (red)

Flashing (red)

The metal halide lamp has turned off automatically because the internal temperature has risen to an abnormally high level.

It is nearly time to replace the lamp unit.

The metal halide lamp switches off automatically.

The air filter may be blocked.

Does “ LAMP” appear on the screen after the projector is turned on?

The power may have been turned on immediately after it was turned off.

There may be an abnormality in the lamp circuit.

Turn off the main power supply by following the procedure on page 11, and then clean the air filter (refer to page 39).

This occurs when the operation time for the lamp unit is nearing 1,800 hours. Ask your dealer or an Authorized Service Center to replace the lamp unit.

Wait for a while until the lamp unit cools down before turning the power back on again.

Turn off the main power supply by following the procedure on page 11, and then contact an Authorized Service Center.

NOTE:

Be sure to turn off the main power by following the procedure given in “Turning the power on and off” on page 11 before carrying out any of the procedures in the “Remedy” column.

If the main power turns off after the TEMP indicator starts flashing, it means that an abnormality has occurred. Please contact an Authorized Service Center so that the necessary repairs can be made.

4 3

Page 44
Image 44
Panasonic PT-L795U Indicators, Lamp indicator Temp indicator Indicator name, Indicator display Problem, Possible cause