12
Auto Pan Key (AUTO PAN KEY)
This setting assigns the SEQ, SORT, AUTO PAN or PATROL (PLAY) mode to the AUTO key on the con-
troller.
After this setting, the AUTO key performs as assigned.
Note: The AUTO PAN LED on the controller does not light if a mode other than AUTO PAN is assigned.
Digital Flip (DIGITAL FLIP)
In ON position, digital flip widens the range to 0° - 180 ° by reversing horizontal and vertical scanning
when the camera is tilted through the 90° (downright position if the camera is installed on a ceiling). If
PAN LIMIT is in ON position, the tilt range is narrowed from 180° to 90 °.
Local/Remote (LOCAL/REMOTE)
This setting determines whether the camera continues or stops the ongoing auto operation when the con-
troller is turned off.
LOCAL: The camera continues operating in the auto mode when the controller is turned off.
REMOTE: The camera stops operating in the auto mode approx. 1 minute after the controller is turned
off.
See page 26 for the setting.
Special 1 Menu
(1) Privacy Zone (PRIVACY ZONE)
This setting is used for masking unwanted zones, hiding them from display on the monitor screen. Set
PASSWORD LOCK to OFF(DIS) if you want to change this setting.
Up to 8 zones can be registered. Submenus are provided for zone number selection and parameter
setting. See page 26 for details.
(2) Proportional Pan-Tilt Speed (PROPO. P/T)
If ON is selected, the pan-tilt speed changes automatically corresponding to the zoom ratio. For
example, the pan-tilt speed slows down when the camera zooms in. See page 28 for details.
(3) Area Title (AREA TITLE)
Up to 8 area titles can be assigned to specific scenes on the DIRECTION (NESW) menu or by
alphanumeric (USER) assignment. The area title is displayed under the camera ID on the monitor
screen when the camera turns to a position that has been assigned an area title. See page 28 for
details.
(4) Patrol-learn and Patrol Play (PATROL)
A set of manual operations is stored (LEARN), reproduced (PLAY) or turned inactive (OFF). Patrol
operation stops if SEQ, SORT or AUTO PAN is set to AUTO MODE on the SETUP menu. See page 30
for details.
(5) Alarm Input/Output (ALARM IN/OUT)
Alarm input and output are set on a submenu. Preset positions are assigned to ALARM IN 1 to 4.
When alarm inputs are supplied via the alarm input connector, the camera turns to the respective
positions. Then the camera sends output signals via the alarm output connector or the coaxial cable
to the external devices. The B/W mode may be chosen if light is insufficient. CNT-CLS (Contact
Closure) 1, 2 and COAX ALM OUT are used for alarm output setting. See page 32 for details.