(9)Digital Noise Reduction (DNR)
DNR may be used to improve quality under low light condi- tions. There are 4 levels of DNR, which may be selected depending on local site conditions. Factory default setting: LOW2
You may need to try different settings to find the most suitable conditions for your application.
Move the cursor to DNR and select LOW1, LOW2, HIGH1 or HIGH2 by moving the joystick to the right or left.
LOW1: DNR level is low. The
LOW2: DNR level is low. The
HIGH1: DNR level is high. The
HIGH2: DNR level is high. The
(10)To Close the SPECIAL2 Menu
Move the cursor to RET and press the CAM (SET) key. The setup menu appears on the monitor screen.
Reset to the Factory Default Settings
Any of the above settings plus the ALC/MANUAL level control and phase adjustments can be reset to the factory default settings by placing the cursor over the desired mode and then pressing the F2 button of the
For the
** SPECIAL2 **
CHROMA GAIN | •••••••• | ||||
AP GAIN | •••••••• | ||||
PEDESTAL | •••••••• | ||||
HUE | •••••••• | ||||
|
| - | + | ||
BW |
|
| OFF | ||
BURST(BW) | → |
| ON | ||
REFRESH | PUSH SW | ||||
CAMERA RESET | → | PUSH SW | |||
DNR |
|
| LOW2 |
| |
RET |
|
|
|
| |
| ** SPECIAL2 ** | ||||
CHROMA GAIN | •••••••• | ||||
AP GAIN | •••••••• | ||||
PEDESTAL | •••••••• | ||||
HUE | •••••••• | ||||
|
| - | + | ||
BW |
|
| OFF | ||
BURST(BW) | → |
| ON | ||
REFRESH | PUSH SW | ||||
CAMERA RESET | → | PUSH SW | |||
DNR |
|
| LOW2 | ||
RET |
|
|
|
|
|
■RS485 Setup
●Initial Camera Communication Parameters
In an RS485 chain, the matrix switcher, PC, controllers and cam- eras should be set to the same protocol and parameters for com- munication. Confirm the system protocol and parameters prior to setting the communication parameters for the camera.
The initial communication parameters for
●Changing the Camera Communication Parameters
You can remotely control this camera by using a specified exten- sion unit such as a computer with a modem.
1.Display the SET UP MENU. Move the cursor to RS485 SET UP and press the CAM (SET) key. The RS485 SET UP menu appears on the monitor.
2.Move the cursor to the item and select the parameter by mov- ing the joystick to the right or left.
RS485 Setup menu
** RS485 SET UP **
UNIT NUMBER | 1 |
|
SUB ADDRESS | ||
BAUD RATE | 19200 | |
DATA BIT | 8 |
|
PARITY CHECK | NONE | |
STOP BIT | 1 |
|
XON/XOFF | NOT USE | |
WAIT TIME | OFF | |
ALARM DATA | AUTO2 | |
DELAY TIME | ||
RET |
|
|
47