(2) ALC Mode with BLC OFF

1.Move the cursor to BLC and select OFF. (When you select MANU- AL, BLC is not available.) The MASK SET appears on the menu.

2.Move the cursor to MASK SET and press the CAM (SET) key. The 48 mask areas appear on the monitor screen. The cursor is blink- ing in the top left corner of the screen.

3.To mask an area where backlight is bright, move the cursor to the area and press the CAM (SET) key. The mask turns white. Repeat this procedure to mask the desired area.

4.To cancel a masked area, move the cursor to the area, and press the CAM (SET) key. To cancel all masking areas, press the F2 button of the WV-CU550B.

For the WV-RM70, press the right and left switches simultaneous- ly.

Turns to white

Blinking

5.After masking is completed, press the MON (ESC) key. The 48 mask areas on the monitor screen disappear and the ALC CONT menu appears.

6.If you want to change the picture contrast, move the “I” cursor for LEVEL and adjust the level.

7.Move the cursor to RET and press the CAM (SET) key to return to the CAM SET UP menu.

To return to the camera picture, press the F4 button.

Blinking

Blinking

** ALC CONT **

BACK LIGHT COMP

BLC

OFF

 

MASK SET

 

 

 

 

 

LEVEL

 

••••••••

 

 

-

+

RET

 

 

 

** ALC CONT **

 

BACK LIGHT COMP

 

BLC

OFF

 

MASK SET

 

 

 

LEVEL

••••••••

 

-

+

RET

38

Page 37
Image 37
Panasonic WV-CW864 operating instructions ALC Mode with BLC OFF, Turns to white Blinking