![](/images/new-backgrounds/1179444/17944461x1.webp)
●Alarm Input/Output (ALARM IN/OUT)
Move the cursor to ALARM IN/OUT, and press the CAM (SET) key. The ALARM IN/OUT submenu appears.
Note: While the camera is in the AF mode or the lens moves between WIDE and TELE, alarm input may be ignored if several alarm inputs are received in succession.
ALARM IN 1-4
Alarm input signals are supplied from external devices through the ALARM IN connector to turn the camera to a preset position.
1.Move the cursor to ALARM IN 1* and select a preset position or OFF by moving the joystick, then press the CAM (SET) key.
The factory default setting is OFF.
*Set ALARM IN 2, 3 and 4 in the same way as ALARM IN 1.
1POSI, 2 POSI, 3 POSI and 4 POSI: Preset position. If an alarm input is received, the camera turns to a preset position, and sends an alarm output signal. The position number corre-
sponds to the alarm input numbers
mode from color to black and white if ALARM IN 4 is sup- plied.
OFF: The camera ignores alarm inputs.
Note: If two or more alarm inputs are received while the camera is moving to a preset position, the camera starts to aim at preset positions in small preset numerical order after current posi- tioning.
CNT-CLS 1, 2 (Output)
Special 1 menu | ||
** SPECIAL 1 ** | ||
PRIVACY ZONE | OFF(ENB) | |
PROPO.P/T | ON | |
AREA TITLE | ON(USER) | |
PATROL | STOP | |
ALARM IN/OUT |
|
|
PASSWORD LOCK | OFF | |
CLEANING | OFF | |
ON | ||
PRESET ALM | OFF | |
IMAGE HOLD | OFF | |
RET |
|
|
ALARM I/O submenu
** | ALARM IN/OUT ** | ||
ALARM | IN | 1 | OFF |
ALARM | IN | 2 | OFF |
ALARM | IN | 3 | OFF |
ALARM | IN | 4 | OFF |
| OFF | ||
TIME | OUT |
| 100MS |
| OFF | ||
COAX ALM OUT | OFF |
RET
Two contact closure signals (Open collector type) are output through the Alarm Output connector.
1.Move the cursor to
The factory default setting is OFF.
When ALARM is selected, TIME OUT appears. Select an appropriate duration from among 100 MS, 200 MS, 1000 MS (1 s), 2000 MS (2 s) or 4000 MS (4 s) by moving the joystick to the right or left.
The factory default setting is 100 MS.
Note: The shorter the duration, the more frequent will be the detection output.
2.Move the cursor to
The factory default setting is OFF.
OFF: Contact closure signals are deactivated.
ALM: Available for
AUX 1(2): An alarm signal is output when the camera receives a command from the controller.
B/W: Available for
Note: It is recommended to set the connected external device to ignore the shorter alarm outputs of 90 ms or less from the camera.