Alarm Input/Output (ALARM IN/OUT)

Move the cursor to ALARM IN/OUT, and press the CAM (SET) key. The ALARM IN/OUT submenu appears.

Note: While the camera is in the AF mode or the lens moves between WIDE and TELE, alarm input may be ignored if several alarm inputs are received in succession.

ALARM IN 1-4

Alarm input signals are supplied from external devices through the ALARM IN connector to turn the camera to a preset position.

1.Move the cursor to ALARM IN 1* and select a preset position or OFF by moving the joystick, then press the CAM (SET) key.

The factory default setting is OFF.

*Set ALARM IN 2, 3 and 4 in the same way as ALARM IN 1.

1POSI, 2 POSI, 3 POSI and 4 POSI: Preset position. If an alarm input is received, the camera turns to a preset position, and sends an alarm output signal. The position number corre-

sponds to the alarm input numbers (1-1, 2-2, 3-3 and 4-4). B/W: Available for ALARM INPUT 4 only. The camera changes its

mode from color to black and white if ALARM IN 4 is sup- plied.

OFF: The camera ignores alarm inputs.

Note: If two or more alarm inputs are received while the camera is moving to a preset position, the camera starts to aim at preset positions in small preset numerical order after current posi- tioning.

CNT-CLS 1, 2 (Output)

Special 1 menu

** SPECIAL 1 **

PRIVACY ZONE

OFF(ENB)

PROPO.P/T

ON

AREA TITLE

ON(USER)

PATROL

STOP

ALARM IN/OUT

 

 

PASSWORD LOCK

OFF

CLEANING

OFF

EL-ZOOM

ON

PRESET ALM

OFF

IMAGE HOLD

OFF

RET

 

 

ALARM I/O submenu

**

ALARM IN/OUT **

ALARM

IN

1

OFF

ALARM

IN

2

OFF

ALARM

IN

3

OFF

ALARM

IN

4

OFF

CNT-CLS 1

 

OFF

TIME

OUT

 

100MS

CNT-CLS 2

 

OFF

COAX ALM OUT

OFF

RET

Two contact closure signals (Open collector type) are output through the Alarm Output connector.

1.Move the cursor to CNT-CLS 1, and select OFF, ALARM or AUX 1 by moving the joystick to the right or left.

The factory default setting is OFF.

When ALARM is selected, TIME OUT appears. Select an appropriate duration from among 100 MS, 200 MS, 1000 MS (1 s), 2000 MS (2 s) or 4000 MS (4 s) by moving the joystick to the right or left.

The factory default setting is 100 MS.

Note: The shorter the duration, the more frequent will be the detection output.

2.Move the cursor to CNT-CLS 2, then select OFF, B/W or AUX 2 by moving the joystick to the right or left.

The factory default setting is OFF.

OFF: Contact closure signals are deactivated.

ALM: Available for CNT-CLS 1 only. A motion detection signal is output.

AUX 1(2): An alarm signal is output when the camera receives a command from the controller.

B/W: Available for CNT-CLS 2 only. ON (active) is output when the camera operates in the black and white mode if ALARM IN 4 is set to B/W.

Note: It is recommended to set the connected external device to ignore the shorter alarm outputs of 90 ms or less from the camera.

32