Access Server Administrators’ Reference Guide

8 • Dial Out

 

 

pppClose(8)—This reason will be given after PPP is initiated and the connection is disconnected. An exam- ple would be if LCP negotiations failed.

lcpClose(9)—close initiated by LCP. This is a normal shutdown of a call.

loginTimeOut(10)—exceeded time limit to login.

userTerminated(11)—the TCP connection was terminated from the remote side.

maxNumCalls(21)—exceeds the maximum number of channels that can be allocated to the same call.

maxLoginAttempts(32)—exceeded maximum login attempts as defined under the dial-out link

noDspAvailable(45)—when the server tried to allocate a DSP for an outbound call but no available DSP’s were available.

papAuthenticationFailure(49)—invalid username/password combination for tcp based calling.

exceedsMultiLinkLimit(64)—exceeds the maximum multilink calls set in the location table.

sessionTimeout(66)—the length of the connection exceeds the session time limit allowed.

noAnswer(85)—the remote modem did not answer the call.

userBusy(86)—the remote location is busy and did not answer the call

noChannelAvail(87)—no channels on the T1/E1 port were available to dialout with.

The following are internal access server errors. Please contact technical support if you see these termination rea- sons on a consistent basis.

noPoll(12)

ipcPutMsgErr(13)

pollErr(15)

ioctlErr(16)

pppPutMsgErr(17)

dspIoctlErr(18)

timerErr(19)

pppOpenErr(22)

pppLinkErr(25)

tcpOpenErr(26)

tcpPushErr(27)

tcpPutMsgErr(28)

invalidPrim(29)

noTimers(33)

tcpLinkErr(34)

dspLinkErr(35)

Dial Out User Statistics Window