Access Server Administrators’ Reference Guide

11 • Digital Signal Processing (DSP)

 

 

DSP information window

This is where you can view and modify parameters for a single DSP.

Figure 63. DSP information window (Call and Debug Statistics)

DSP Status

This portion of the DSP information window shows information about the overall status of the selected DSP.

Desired State (dspDesiredState)

The state of the DSP desired by the administrator—this state may be different than its actual state.

pendingReboot(1)—This will put the individual DSP into the pendingBoot reset state and reserve all DSPs in the group. It will not perform the reboot until there are no calls in the group of associated DSPs, or until 10 minutes have elapsed, at which point it will disconnect any remaining calls to do the reboot.

RebootNow(2)—This will disconnect all calls on the group of associated DSPs and perform the DSP reboot immediately.

unavailable(3)—DSP has been taken out of the resource pool

available(4)—DSP is available for use

availableFirstOnly(17)—Marks the second instance of the DSP unavailable.

availableSecondOnly(18)—Marks the first instance of the DSP available.

forceDerail(19)—This is for use by the engineers and technical support for testing purposes only. Do not use.

DSP information window

151

Page 151
Image 151
Patton electronic 29XX manual DSP information window, DSP Status, Desired State dspDesiredState