The following settings must match the line configuration provided by the local telephone company. For more information on setting up your T1/E1, see the Model 29xx Series RAS User Manual available online at www.patton.com/manuals/29xx.pdf.

4.Click on the Line Type drop-down menu and choose one of the following options:

For a T1 line, select dsx1ESF(2) (Extended SuperFrame DS1) or dsx1D4(3) (A&T D4 format DS1).

For an E1 line, choose dsx1E1(4) or dsx1E1-CRC(5).

5.Click on the Line Coding drop-down menu and choose one of the following options:

For T1: If you selected dsx1D4(3) line type, select dsx1AMI(5) line coding. If you selected dsx1ESF(2) line type, choose dsx1B8ZS(2) line coding.

For E1: Select dsx1AMI(5) or dsx1HDB3(3). Most installations will use HDB3.

6.Click on the Line Build Out drop-down menu and choose one of the following options:

For T1: Select t1pulse0dB(2).

For E1, select e1pulse(1).

7.Click Submit.

8.Select none for Signalling Protocol.

9.Click Submit.

At this point, the access server’s front panel LEDs should now be showing signs that the line is active. If the phone company line is not connected to the access server, the error indicator will glow red for that line/connection.

WAN Channel Assignment main screen

The next stage in configuring a Frame Relay link is to set the number of 64-kbps channels on the T1/E1 that will carry the data. Each channel is 64 kbps in speed and must correspond to the same channels that your pro- vider is using. Usually your provider will start from channel 1. For example: a 256-kbps link could be divided into 64-kbps channels numbered 1, 2, 3, and 4.

To set the channel assignment:

1.Click on T1/E1 Link under the Configuration Menu to display the T1/E1 Link Activity main window (see figure 102 on page 252).

2.Click on Channel Assignment in the appropriate Link: x section (for example, if the T1/E1 cable was con-

nected to port 2, you would click on Channel Assignment in the Link: 2 section).

3.Click on the appropriate channel’s drop-down menu and select frameRelay(3).

4.Repeat step 3 to configure remaining channels.

5.Click Submit.

The link should now be activated on your access server. The next stages will configure Frame Relay and IP routing.