D a t a F o r m a t t i n g F a i l u r e s

Formatting errors indicate that a field will print incorrectly. After you have checked the data stream and corrected the data, retransmit the format and batch.

For these errors, the batch still prints, but the

field, font, bar code, or density may be incomplete, missing or contain incorrect data.

574No CD scheme or room for CD. The CD scheme in the batch does not fit the format or the field contains blanks.

575The graphic included in your format could not be found.

611Font, bar code or density is invalid. The font, bar code or density in the batch does not fit the format.

612The data in this line of the batch is either missing or does not match the format.

613Reference point off tag.

614Portion of field off tag. There may be an invalid character in the packet. Make sure you did not enter O for Ø.

616Dot shifting failed. A bad dot falls on a bar code that cannot be shifted. Call Technical Support.

618 Magnification must be 1 - 7.

621An error occurred opening the TrueType font file. Select a different font to download. If the error message persists, call Technical Support.

Troubleshooting 8-15

Page 153
Image 153
Paxar 2 manual T a F o r m a t t i n g F a i l u r e s