Paxar 2 I n g C h e c k D i g i t s, Selector,action,device,modulus, Fldlength,D/P,weights p

Models: 2

1 234
Download 234 pages 15.18 Kb
Page 91
Image 91

U s i n g C h e c k D i g i t s

Check digits are typically used to ensure that a text or bar code field scans correctly. If you apply Option 31, the printer calculates a check digit. A check digit scheme determines how the printer calculates a check digit. When you define a check digit scheme, you assign a number to identify it. This number is later entered in box R4 when you apply Option 31 to a field. You can use check digits with text or bar code fields. Check digit calculations are performed on numeric data only.

Do not use check digits with price fields. Do not define a check digit scheme for these bar codes, because they have predefined check digits: UPC, EAN, Code 39 (with the MOD43 check digit), and Code 93.

Syntax

 

{A,selector,action,device,modulus,

 

 

 

fld_length,D/P,"weights" p }

A1.

A

Check Digit Header.

A2.

selector

Assign a number from 1 - 10 to this check digit formula.

A3. action

The action to perform. Enter A to add the check digit scheme.

A4. device

Device. Use R.

A5. modulus

Number from 2 - 11. The modulus is used to divide the sum

 

 

of products or the sum of digits.

A6.

fld_length

The maximum number of characters the field will contain.

 

 

Range: 0 - 2710.

A7.

D/P

Algorithm. The algorithm determines how the check digit is

 

 

calculated. Options:

 

 

D

sum of digits

 

 

P

sum of products

A8.

"weights"

String of digits used for calculation. A weight string is a group

 

 

of two or more numbers that is applied to a field. The number

 

 

of digits in this string should equal the number in fld_length.

 

 

Enclose in quotation marks. Range: 0 - 2710.

Defining Field Options 4-15

Page 91
Image 91
Paxar 2 manual I n g C h e c k D i g i t s, Selector,action,device,modulus, Fldlength,D/P,weights p