<MAIN MENU>
DISPLAY
TIMER PROGRAM
RECORDING SET UP
REAR TERMINAL
MAINTENANCE CLOCK/FIRST TIME SET UP
Use JOG to select, and ENTER.
Press MENU to exit.
00472
<RECORDING SET UP> |
|
ALARM REC MODE | 8H |
ALARM REC DURATION | 1M |
EMERGENCY REC | ON |
| 00473 |
<RECORDING SET UP> |
|
ALARM REC MODE | 8H |
ALARM REC DURATION | 1M |
EMERGENCY REC | ON |
| 00474 |
<RECORDING SET UP> |
|
ALARM REC MODE | 8H |
ALARM REC DURATION | 1M |
EMERGENCY REC | ON |
00475
NOTE: If an alarm input is received during alarm recording, a new alarm recording will start with the new input signal.
PROGRAMMING FOR ALARM RECORDING
Alarm recording will continue for the period set in the ALARM REC DURATION field, even if a timer recording has reached its end time.
Alarm recording stops when the end of the tape is reached.
Emergency recording activates alarm recording even if the VCR is off, stopped, or in timer recording or standby modes. The emergency recording indicator (EMGCY) on the fluorescent display lights provided EMERGENCY REC is ON. After an emergency recording, the VCR automatically returns to its original state.
You should set the alarm recording mode in the Recording Set Up menu before using alarm recording.
1.Press the MENU button. The Main menu appears.
2.Turn the JOG dial to select RECORDING SET UP, and then turn the SHUTTLE ring right. The Recording Set Up menu appears.
3.When the cursor is next to ALARM REC MODE, turn the SHUTTLE ring right.
4.Turn the JOG dial to set the alarm recording mode you want, and then turn the SHUTTLE ring right.
5.Turn the JOG dial to select ALARM REC DURATION, and then turn the SHUTTLE ring right.
6.Turn the JOG dial to set the alarm recording duration you want, and then turn the SHUTTLE ring right.
•When set to MAN1, alarm recording continues until the RST (reset) IN terminal is grounded.
•When set to MAN2, alarm recording continues while the ALM IN terminal is grounded.
•You can adjust the internal time clock by applying a signal to the RST IN terminal when ALARM REC DURATION is set to other than MAN1.
7.If you wish to activate emergency recording, turn the JOG dial to select EMERGENCY REC, and then turn the SHUTTLE ring right. Turn the JOG dial to select ON for emergency recording. The emergency recording indicator (EMGCY) lights on the fluorescent display.
8.Press the MENU button. The day and time display appears.
During alarm recording, the alarm recording count is displayed automatically except when Display Mode 4 (display nothing) is selected.
•The alarm recording count display counts up to 9999 alarm recordings and then resets to 0000 and continues counting.
•When initializing the alarm recording list, the alarm recording count display is reset.
•The alarm indicator (ALARM) flashes during alarm recording and stays lit when the alarm recording finishes.
•When alarm recording finishes, the VCR resumes recording in the same mode as before the alarm recording.
•If you are programming on any of the menus and an alarm input signal is received at the ALM IN terminal, alarm recording begins and the menu being programmed disappears from the screen.
Pelco Manual C673M (2/01) | 45 |