Pioneer DRM-7000 operating instructions Auto probing?, A u t o p r o b i n g i s set to ON / OFF

Models: DRM-7000

1 52
Download 52 pages 15.69 Kb
Page 29
Image 29
Auto probing?

DRM-7000Operating Instructions

The optional operations are as follows when scanning using the right arrow button:

Auto Probing – default set to OFF at time of shipment

Inquiry Change – default set to OFF at time of shipment

Free Message – default set to Off at time of shipment

Alert Buzzer – default set to ON at time of shipment

Hyper I/E – default set to ON at time of shipment

Auto Eject – default set to ON at time of shipment

Hot Start – default set to OFF at time of shipment

5.2.3.1Auto Probing

When standard 50-disc and hyper magazines have discs added while outside of the DRM-7000, the system requires a slot check before accessing the new discs. An Auto Probe command checks all magazine slots in sequence to determine whether each slot is empty or full. The Controller software usually performs this check. However, if the software fails to support this activity or the Changer is disconnected from a host computer, use the Auto Probing function.

Commands from the host computer are ignored during an Auto Probe issued through the controller program.

Even after switching Auto Probing from OFF to ON, the feature is unavailable until an access door is opened then closed or until the unit is reset.

Auto probing?

Press the Enter button

A u t o p r o b i n g i s set to ON / OFF

Press the left arrow button

A u t o p r o b i n g i s set to ON / OFF

Press the Enter button

A u t o p r o b i n g

i s a c t i v a t e d

- 25 -

Page 29
Image 29
Pioneer DRM-7000 Auto probing?, A u t o p r o b i n g i s set to ON / OFF, A u t o p r o b i n g i s a c t i v a t e d