Battery sealing ring:

Silicone

 

Operating temperature:

-10 °C to +50 °C / 14 °F to 122 °F

Training computer materials:

PMMA lens with hard coating in top surface, training computer body

 

ABS+GF metal parts stainless steel

Wrist strap and buckle materials:

Polyurethane (TPU)/Silicone, stainless steel

Watch accuracy:

Better than ± 0.5 seconds / day at 25 °C / 77 °F temperature.

Accuracy of heart rate monitor:

± 1% or 1 bpm, whichever larger. Definition applies to stable conditions.

Heart rate measuring range:

15-240

 

Current speed display range:

0-127 km/h or 0-75 mph (when measuring speed with s3+ stride sensor

 

or CS speed sensor)

 

 

0-400 km/h or 0-248.5 mph (when measuring speed with G5/G3 GPS

 

sensor)

 

Water resistance:

30 m (Suitable for bathing and swimming)

Training computer limit values

 

 

Maximum number of files:

 

99

Maximum time recorded to file:

 

99 h 59 min 59 s

Maximum time recorded to file with different sensor combinations:

 

Heart rate

 

99

Heart rate + stride sensor

26

Heart rate + GPS sensor

15

Heart rate + CS speed sensor

32

Heart rate + CS cadence sensor

61

Heart rate + stride sensor + GPS sensor

14

Heart rate + GPS sensor + CS speed sensor

15

Heart rate + GPS sensor + CS cadence sensor

14

Heart rate + CS speed sensor + CS cadence

26

sensor

 

 

Heart rate + GPS sensor + CS speed sensor +

14

CS cadence sensor

 

 

Stride sensor

 

32

Stride sensor + GPS sensor

15

GPS sensor

 

17

GPS sensor + CS speed sensor

17

GPS sensor + CS cadence sensor

15

GPS sensor + CS speed sensor + CS cadence

15

sensor

 

 

CS speed sensor

 

40

CS cadence sensor

 

99

CS speed sensor + CS cadence sensor

32

The training computer stores the data in five second intervals.

Maximum number of laps recorded in one training session:

99

Maximum number of automatic laps recorded in one training session:

99

Total distance:

 

99999.99 km / 99999.99 mi

Total duration:

 

9999 h 59 min 59 s

Total calories:

 

999 999 kcal

Total training files count:

 

65535

Heart rate sensor

 

 

Battery life of WearLink® transmitter W.I.N.D.:

Average 2000 hours of use

 

Battery type:

CR2025

 

Battery sealing ring:

O-ring 20.0 x 1.0, material silicone

Operating temperature:

-10 °C to +40 °C / 14 °F to 104 °F

Connector material:

Polyamide

 

Strap material:

Polyurethane/Polyamide/Polyester/Elastane/Nylon

Water resistance:

30 m (Suitable for bathing and swimming).

 

The WearLink W.I.N.D. transmitter does not measure heart rate in water.

The Polar RCX3 training computer applies the following patented technologies, among others:

Important Information

49

Page 49
Image 49
Polar RCX3 user manual Training computer limit values