Sites  Site Topology
Polycom, Inc.  275
ISDN Number Ranges  The number ranges available for assignment to 
endpoints in the site. 
Click Add to add a new range of numbers. Click Edit or 
Delete to change or delete the selected range. 
The start and end numbers in the range should be 
entered with the same number of digits. If the range is 
303-223-1000 to 1999, enter 3032231000 and 
3032231999. 
ISDN Range Assignment (for gateway extension dialing method) 
ISDN gateway number  An ISDN gateway phone number for the site. This field 
is just for your reference. It’s not used by the software to 
process calls. 
If the site has more than one ISDN gateway, you’ll need 
to know their access numbers and determine how to 
instruct inbound users to call. 
E.164 start  The beginning of the range of E.164 extensions 
associated with the site. 
E.164 end  Th e end of the range of E.164 extensions associated 
with the site. 
The start and end numbers in the range should be 
entered with the same number of digits. 
H.323 Routing 
Internet calls are not 
allowed 
Disables H.323 calls to the internet. 
Allowed via 
H.323-aware firewall 
Allows H.323 calls to the internet through a firewall. 
Allowed via 
H.323-aware SBC or 
ALG 
Allows H.323 calls to the internet only through an H.323 
session border controller (SBC) or application layer 
gateway (ALG). 
Call signaling address 
(IPv4) 
The call signaling address for the H.323 SBC. 
Port  The call signaling port for the H.323 SBC. 
SIP Routing 
Internet calls are not 
allowed 
Disables SIP calls to the internet. 
Allowed via SIP-aware 
firewall 
Enables calls to the internet through a firewall. 
Allowed via SIP-aware 
SBC or ALG 
Enables calls to the internet through a session border 
controller (SBC) or application layer gateway (ALG). 
Table 11-4 Edit Site dialog box (continued)
Field Description