Alerts  System Management and Maintenance
Polycom, Inc.  345
See also:
“Alerts” on page 338 
Alert 2201 Calendaring primary integration cluster <p-cluster> is not operational. 
Integration by backup cluster <b-cluster>. 
The primary cluster for the territory responsible for Exchange server 
integration is unreachable, and its backup cluster has taken over responsibility 
for monitoring the Polycom Conferencing user mailbox and accepting or 
declining the meeting invitations received. 
This may indicate a network problem. It’s also possible that someone shut the 
cluster down or that it failed. 
Click the link to go to the DMAs page to begin troubleshooting. 
See also:
“Alerts” on page 338 
Alert 2202 Calendaring service is not available. Both primary cluster <p-cluster> and 
backup cluster <b-cluster> are not operational. 
The primary and backup clusters for the territory responsible for Exchange 
server integration are both unreachable. 
This may indicate serious network problems. It’s also possible that someone 
shut both clusters down, or shut down one and the other then failed, or both 
failed (unlikely). 
Click the link to go to the DMAs page to begin troubleshooting. Determine 
whether the clusters were deliberately shut down. If not, try pinging the 
clusters’ IP addresses. 
See also:
“Alerts” on page 338 
Alert 2203 Calendaring service is not available. Cluster <p-cluster> is not operational 
The primary cluster for the territory responsible for Exchange server 
integration is unreachable, and it has no backup cluster. 
This may indicate a network problem. It’s also possible that someone shut the 
cluster down or that it failed.