Polycom DOC2232A manual MCUs Cards Status

Models: DOC2232A

1 132
Download 132 pages 43.7 Kb
Page 105
Image 105

Chapter 8 - MGC-25 Management Tools

Table 8-5: MCU's Cards Status

Field

Description

 

 

Slot

Displays the slot icon and number; a white icon

 

indicates an empty slot and a green icon indicates

 

an occupied slot.

 

 

Type

Displays the type of card that occupies the slot. The

 

following card types are available, as listed in

 

Table 8-4.

 

 

Clock

This field is valid only for Net-2 cards. It indicates

 

which Network card/span is used as the Master

 

Clock.

 

 

Configured Clock

Indicates which ISDN Network card was configured

 

as the Primary network interface (for clocking).

 

Changes take effect and are updated during the next

 

MCU reset or power up.

 

 

Status

Indicates the card status: Normal or Faulty.

 

 

Occupied Units

Indicates the units that are currently used to run

 

conferences by displaying their sequential number

 

on the card. For example, 1, 6 indicates that two

 

units, unit # 1 and unit # 6 are used to run

 

conferences.

 

 

Faulty Units

Indicates whether there are units on the card that

 

are faulty and the displays the sequential number of

 

the faulty unit.

 

 

Disabled Units

Indicates the units that were disabled by the

 

operator. The units may be disabled using the card's

 

right-click menu.

 

 

Num Units

Indicates the total number of units available for each

 

module.

 

 

For additional information, see the MGC Manager Administrator’s Guide, Chapter 4.

The configuration of each card can be checked and for specific cards, modified if required. Any operator can view the card’s configuration settings. Only an operator defined as Superuser can modify the configuration settings of a card.

8-11

Page 105
Image 105
Polycom DOC2232A manual MCUs Cards Status