The maximum rate of any one stream’s delivery is practically limited to the maximum possible scan and data conversion rate of all the module’s channels. Normally, these programmable host streams deliver host data at rates equal to or slower than this natural cycle. For a typical application, the first stream delivers a few channels, at a high rate (as defined by a hardware trigger). The second stream delivers other channels at a medium rate (some multiple of the trigger period), and the third stream can deliver still other channels at a slower rate (also a multiple of the trigger period).

Avoid confusing this Configure/Control Autonomous Host Streams Note command 'c' (lower case c) with the Configure/Control Multi-Point

Calibration command 'C' (upper case C). Like 'C', but unlike most other module commands, all sub-commands of this command require a space between the command id ('c') and the

first parameter (ii).