Pressure Systems 98RK-1 bbbb hex, data selected for inclusion in each stream packet, 0001, 0002

Models: 98RK-1

1 153
Download 153 pages 51.42 Kb
Page 72
Image 72
bbbb (hex)

Pressure Systems, Inc.

98RK-1 & 9816 User’s Manual©

 

 

 

 

 

 

 

 

 

 

bbbb (hex)

data selected for inclusion in each stream packet

 

 

 

 

 

 

 

 

 

 

0001

Enable Valve Position Status (see next table)

 

 

 

 

0002

Enable DH Temperature Status (see bit map below)

 

 

 

 

0010

Enable Pressure EU Data (default if never executed)

 

 

 

 

0020

Enable Pressure A/D Counts*

 

 

 

 

0040

Enable Pressure Voltages*

 

 

 

 

0080

Enable DH Temperature EU Data (degrees C)*

 

 

 

 

0100

Enable DH Temperature A/D Counts*

 

 

 

 

0200

Enable DH Temperature Voltages*

 

 

Any Valve Position Status datum is delivered as a two-byte binary integer (16-bit, big endian) with the following possible values (shown in hex below). If selected, this datum will follow the stream header in each packet:

 

 

 

 

 

 

 

 

status (hex)

Valve Position Status

 

 

 

 

 

 

 

 

 

 

0000

Valves in RUN position

 

 

 

 

0001

Valves in CAL position

 

 

 

 

0010

Valves in LEAK/CHARGE position

 

 

 

 

0011

Valves in PURGE position

 

 

Any DH Temperature Status datum is delivered as a two-byte binary bit map (16-bit, big endian) with each bit representing the status of DH #16 through DH #1 respectively. A bit value of 0 (zero) indicates the DH is operating within its specified limits. A value of 1 (one) indicates the DH is outside its specified limits.

Bit #

Chan # Binary

Hex

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

 

0

0

0

0

 

0

0

0

0

 

0

0

0

0

 

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

0

 

 

 

0

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The above example indicates that Channels 1 and 16 are operating outside the specified temperature limits. This binary datum, when selected, follows the previous Valve Position status datum (or the stream packet header).