Proxim CPN 63708 Viewing and Changing Parameters, Entering Strings, Show Command, Set Command

Models: CPN 63708

1 83
Download 83 pages 8.21 Kb
Page 61
Image 61

Tsunami MP.11 Installation and Management

VIEWING AND CHANGING PARAMETERS

You can view and change MP.11 parameters with the SHOW and SET commands, respectively. These commands are described below.

Show Command

The show command lets you view parameter and statistical values. You can view a single parameter, a group of parameters, or a table with parameters. A table consists of rows with similar parameters.

Example: To view all system parameters:

show system

This shows the current values of the system parameters.

Set Command

The set command lets you change parameter values. You can change a single parameter value and you can also modify a group of parameters, or a table with parameters. If a parameter requires more than one value, the values must be separated by spaces.

Example: To set the MP.11 IP address parameter:

set ipaddrtype static

set ipaddr 1 ipaddress 10.0.0.12

Some parameter values change only when the MP.11 is rebooted. In these cases, the CLI warns you that a reboot is required for the change to take effect.

ENTERING STRINGS

If you need to enter a string with spaces, you must use single or double quotes. For example, there is no need for quotes in the following because the string does not contain spaces:

set sysname Lobby

The following string, however, requires quotes because of the space between the words Front and Lobby.

set sysname “Front Lobby”

Chapter 6. Command Line Interface