A

3 – Event Messages Alarm Events

(A1007.0020) (MAX Retry count reached on CHAP Authentication Protocol Reset, failing Authentication)

Meaning:

A RADIUS server has rejected a RADIUS authentication request.

Action:

Check the configuration on both the switch and on the RADIUS

 

Server for incompatibilities.

(A1007.0021) (No response to RADIUS access request for device on port port)

Meaning:

A configured RADIUS server did not respond to an authentication

 

request within the timeout period.

Action:

Check RADIUS server configuration and the RADIUS server.

(A1007.0022) (Invalid response authenticator from RADIUS server IP_address:port, check shared secret)

Meaning:

RADIUS server configuration issue.

Action:

Check the shared secret. The shared secret must be configured on

 

both the RADIUS server and the switch.

(A1007.0023) (Invalid response authenticator from RADIUS server IP_address:port, check

shared secret

 

Meaning:

There is a RADIUS configuration problem.

Action:

Confirm that the shared secret configured on the switch is identical

 

to the shared secret configured on the RADIUS server.

(A1007.0024) (Invalid access accept from RADIUS server IP_address:port, bad or missing

Service-Type)

 

Meaning:

A service-type RADIUS attribute was not found within a RADIUS

 

packet.

Action:

This is a RADIUS Server configuration issue. Consult your

 

RADIUS server documentation.

(A1007.0025) (Security feature not supported.)

Meaning:

The switch is coming out of Non-Disruptive Code Load and

 

Activation (NDCLA) and had an active security prior to the NDCLA,

 

but the security feature is no longer supported.

Action:

A license key may be required for the security feature.

(A1007.0026) (Unable to validate Chap Response from device_WWN, possible Chap secret misconfiguration or security breach attempt.)

Meaning:

A CHAP authentication attempt failed due to failure while

 

comparing secrets.

Action:

Check security configuration.

59060-02 B

3-25

Page 37
Image 37
Q-Logic 59060-02 B manual A1007.0025 Security feature not supported

59060-02 B specifications

The Q-Logic 59060-02 B is a cutting-edge Fibre Channel host bus adapter (HBA) designed to optimize data transfer rates and enhance connectivity in high-performance computing environments. This advanced HBA is particularly suited for enterprise data centers that demand robust and reliable storage solutions, capable of handling large volumes of data with minimal latency.

One of the main features of the Q-Logic 59060-02 B is its dual-channel architecture, which allows for simultaneous data transfer across two separate Fibre Channel connections. This dual-channel capability effectively doubles the data throughput compared to single-channel adapters, providing seamless scalability for growing storage demands. The HBA supports data rates of up to 2 Gbps, ensuring rapid access to storage devices and enhanced performance for applications requiring high bandwidth.

The Q-Logic 59060-02 B also incorporates advanced technologies that enhance its functionality and performance. One such technology is its integrated hardware acceleration for offloading tasks like error correction and flow control from the host CPU. This offloading conserves system resources, allowing the CPU to focus on other critical tasks and improving overall system efficiency.

In addition, the adapter is designed for easy integration with existing storage networks, thanks to its compliance with SCSI standards and support for various operating systems, including Windows and Linux. This compatibility makes the Q-Logic 59060-02 B a versatile solution for diverse IT environments.

Security is another critical aspect of the Q-Logic 59060-02 B. The adapter includes built-in features for secure data transmission, including advanced encryption capabilities that protect sensitive information traveling across the network. This focus on security helps organizations safeguard their data integrity and comply with industry regulations.

Another noteworthy characteristic of the Q-Logic 59060-02 B is its robustness and reliability. The HBA is designed to handle rigorous data workloads and can operate in demanding conditions typical of data center environments. With its superior quality and performance capabilities, the Q-Logic 59060-02 B remains a preferred choice for enterprises looking to enhance their data storage and retrieval systems while maintaining high levels of performance and security.