Diagnostic testing has determined that there is a partial failure on specified I/O blade. Most likely, at least one of the ports did not pass the Power-On-Self-Test (POST).
Enter the Show Post Log command to investigate.

A

3 – Event Messages Alarm Events

(A3004.0001) (Non-fatal hardware error detected. Use 'show post log' for more info)

Meaning:

A non-fatal hardware error was discovered during the

 

Power-On-Self-Test (POST) phase of startup.

Action:

Enter the Show Post Log command to investigate.

(A3004.0002) (Diagnostics have detected a partial failure on the I/O blade in slot slot_number)

Meaning:

Action:

(A3008.0000) (The configuration area was damaged or a Remake Filesystem was performed from PROM mode. You must perform a 'config restore' to clear this error.)

Meaning:

The configuration area was damaged or a Remake Filesystem was

 

performed from Maintenance mode.

Action:

Enter the Config Restore command to clear the error. If this does

 

not correct the problem, contact your authorized maintenance

 

provider.

(A3014.0001) (Blade in slot slot_number set Down due to failure of all AuxPorts)

Meaning:

The blade in the named slot has isolated because all auxiliary ports

 

to the cross-connect blades have failed.

Action:

Contact your authorized maintenance provider.

(A3014.0002) (Blade in slot slot_number set Online due to internal failure recovery)

Meaning:

The blade in the named slot has recovered at least one auxiliary

 

port to a cross-connect blade and is no longer isolated.

Action:

None

(A3014.0003) (Blade blade_ID set Down due to blade type mismatch)

Meaning:

The I/O blade given by blade_ID has isolated because the

 

operational blade type does not match the configured blade type.

Action:

Change the configured blade type to match the I/O blade that is

 

present, or insert an I/O blade of the configured blade type.

(A4000.0001) (threshold of value hit rising trigger trigger_number in value second window on port port_number - ALARM SET

Meaning:

The switch exceeded the specified threshold rising trigger in the

 

specified sample window.

Action:

Investigate the specified port for problems or adjust the rising

 

trigger or sample window.

59060-02 B

3-31

Page 43
Image 43
Q-Logic 59060-02 B manual A3014.0003 Blade bladeID set Down due to blade type mismatch

59060-02 B specifications

The Q-Logic 59060-02 B is a cutting-edge Fibre Channel host bus adapter (HBA) designed to optimize data transfer rates and enhance connectivity in high-performance computing environments. This advanced HBA is particularly suited for enterprise data centers that demand robust and reliable storage solutions, capable of handling large volumes of data with minimal latency.

One of the main features of the Q-Logic 59060-02 B is its dual-channel architecture, which allows for simultaneous data transfer across two separate Fibre Channel connections. This dual-channel capability effectively doubles the data throughput compared to single-channel adapters, providing seamless scalability for growing storage demands. The HBA supports data rates of up to 2 Gbps, ensuring rapid access to storage devices and enhanced performance for applications requiring high bandwidth.

The Q-Logic 59060-02 B also incorporates advanced technologies that enhance its functionality and performance. One such technology is its integrated hardware acceleration for offloading tasks like error correction and flow control from the host CPU. This offloading conserves system resources, allowing the CPU to focus on other critical tasks and improving overall system efficiency.

In addition, the adapter is designed for easy integration with existing storage networks, thanks to its compliance with SCSI standards and support for various operating systems, including Windows and Linux. This compatibility makes the Q-Logic 59060-02 B a versatile solution for diverse IT environments.

Security is another critical aspect of the Q-Logic 59060-02 B. The adapter includes built-in features for secure data transmission, including advanced encryption capabilities that protect sensitive information traveling across the network. This focus on security helps organizations safeguard their data integrity and comply with industry regulations.

Another noteworthy characteristic of the Q-Logic 59060-02 B is its robustness and reliability. The HBA is designed to handle rigorous data workloads and can operate in demanding conditions typical of data center environments. With its superior quality and performance capabilities, the Q-Logic 59060-02 B remains a preferred choice for enterprises looking to enhance their data storage and retrieval systems while maintaining high levels of performance and security.