3 – Event Messages Alarm Events

S

(A1007.0032) (Fabric conditions or configurations do not currently allow for changing fabric binding.)

Meaning:

An attempt to change the fabric binding setting was rejected due to

 

current fabric binding configuration settings within the active

 

security set.

Action:

Check fabric binding settings and the domain IDs of the switches

 

within the fabric. Add missing switches to the ISL group of the

 

active security set.

(A1007.0033) (Device device_WWN failed port binding.)

Meaning:

A device attempted FLOGI, but that device was not configured in

 

the port binding list for the specified port.

Action:

Add the device to the port binding list.

(A1007.0034) (Device device_wwn failed switch binding.)

Meaning:

A device attempted FLOGI, but that device was not configured in

 

the switch binding list for the specified switch.

Action:

Add the device to the switch binding list.

(A1007.0035) (Port taken offline due to switch binding failure following configuration change.)

Meaning:

A configuration change was made to the switch binding list such

 

that the device(s) on the port were no longer allowed to be logged

 

in.

Action:

Add the devices to the switch binding list.

(A1007.0036) (Port taken offline due to port binding failure following configuration change.)

Meaning:

A configuration change was made to the port binding list such that

 

the device(s) on the port were no longer allowed to be logged in.

Action:

Add the devices to the port binding list.

(A1007.0037) (Device device_wwn failed port binding)

Meaning:

A switch device attempted to login as ISL but that device was not

 

configured in the Port Binding list for the specified port.

Action:

Add the device to the port binding list.

(A1007.0038) (Device device_wwn failed switch binding)

Meaning:

A switch device attempted to login as ISL but that device was not

 

configured in the Switch Binding list.

Action:

Add the device to the switch binding list.

3-28

59060-02 B

Page 40
Image 40
Q-Logic 59060-02 B A1007.0033 Device deviceWWN failed port binding, A1007.0034 Device devicewwn failed switch binding

59060-02 B specifications

The Q-Logic 59060-02 B is a cutting-edge Fibre Channel host bus adapter (HBA) designed to optimize data transfer rates and enhance connectivity in high-performance computing environments. This advanced HBA is particularly suited for enterprise data centers that demand robust and reliable storage solutions, capable of handling large volumes of data with minimal latency.

One of the main features of the Q-Logic 59060-02 B is its dual-channel architecture, which allows for simultaneous data transfer across two separate Fibre Channel connections. This dual-channel capability effectively doubles the data throughput compared to single-channel adapters, providing seamless scalability for growing storage demands. The HBA supports data rates of up to 2 Gbps, ensuring rapid access to storage devices and enhanced performance for applications requiring high bandwidth.

The Q-Logic 59060-02 B also incorporates advanced technologies that enhance its functionality and performance. One such technology is its integrated hardware acceleration for offloading tasks like error correction and flow control from the host CPU. This offloading conserves system resources, allowing the CPU to focus on other critical tasks and improving overall system efficiency.

In addition, the adapter is designed for easy integration with existing storage networks, thanks to its compliance with SCSI standards and support for various operating systems, including Windows and Linux. This compatibility makes the Q-Logic 59060-02 B a versatile solution for diverse IT environments.

Security is another critical aspect of the Q-Logic 59060-02 B. The adapter includes built-in features for secure data transmission, including advanced encryption capabilities that protect sensitive information traveling across the network. This focus on security helps organizations safeguard their data integrity and comply with industry regulations.

Another noteworthy characteristic of the Q-Logic 59060-02 B is its robustness and reliability. The HBA is designed to handle rigorous data workloads and can operate in demanding conditions typical of data center environments. With its superior quality and performance capabilities, the Q-Logic 59060-02 B remains a preferred choice for enterprises looking to enhance their data storage and retrieval systems while maintaining high levels of performance and security.