A

3 – Event Messages Alarm Events

(A1003.0013) (Segmenting, zone zone_name merge conflict)

Meaning:

In non-interop mode, there is a conflict in the zoning configuration,

 

causing the Inter-Switch Link (ISL) to isolate. After a zone merge

 

with interop mode disabled, two zone were discovered in the local

 

zoning database with the same name, but different membership.

Action:

Contact your authorized maintenance provider.

(A1003.0014) (Segmenting, alias alias_name merge conflict)

Meaning:

There is a conflict in the zoning configuration causing the

 

Inter-Switch Link (ISL) to isolate. Two aliases were discovered in

 

the local zoning database with the same name, but different

 

membership.

Action:

Reconcile the active zone sets so that the two aliases have

 

identical membership.

(A1003.0015) (Zoneset Activation received from switch with domain domain_ID failed, unknown zoneset zone_set_name)

Meaning:

A zone set activation received from the named switch failed

 

because the zone set was not in the zoning database.

Action:

Examine the named switch to verify that the zoning database is

 

correct.

(A1003.0016) (Releasing Lock held too long by domain_ID)

Meaning:

Zone merge could not complete in the acceptable time.

Action:

Check the status of the switch given by domain_ID.

(A1003.0017) (Activation of zoneset by management server failed due to port port_number out of range.)

Meaning:

A zone member defined by domain ID and port was received within

 

a management server AZSD command with a port number out of

 

range.

Action:

Check management server application zoning configuration to

 

assure zone members are properly configured.

(A1003.001B) (Failing remote zoning configuration, total zoneset limit would be exceeded)

Meaning:

The maximum number of zone sets has been exceeded on the

 

switch as a result of a zone merge.

Action:

Reduce the number of zone sets on the remote switch.

(A1003.001C) (Failing remote zoning configuration, total member limit would be exceeded)

Meaning:

The maximum number of zone members has been exceeded on

 

the switch due to a zone merge.

Action:

Reduce the number of zone members on the remote switch.

59060-02 B

3-3

Page 15
Image 15
Q-Logic 59060-02 B manual A1003.0013 Segmenting, zone zonename merge conflict

59060-02 B specifications

The Q-Logic 59060-02 B is a cutting-edge Fibre Channel host bus adapter (HBA) designed to optimize data transfer rates and enhance connectivity in high-performance computing environments. This advanced HBA is particularly suited for enterprise data centers that demand robust and reliable storage solutions, capable of handling large volumes of data with minimal latency.

One of the main features of the Q-Logic 59060-02 B is its dual-channel architecture, which allows for simultaneous data transfer across two separate Fibre Channel connections. This dual-channel capability effectively doubles the data throughput compared to single-channel adapters, providing seamless scalability for growing storage demands. The HBA supports data rates of up to 2 Gbps, ensuring rapid access to storage devices and enhanced performance for applications requiring high bandwidth.

The Q-Logic 59060-02 B also incorporates advanced technologies that enhance its functionality and performance. One such technology is its integrated hardware acceleration for offloading tasks like error correction and flow control from the host CPU. This offloading conserves system resources, allowing the CPU to focus on other critical tasks and improving overall system efficiency.

In addition, the adapter is designed for easy integration with existing storage networks, thanks to its compliance with SCSI standards and support for various operating systems, including Windows and Linux. This compatibility makes the Q-Logic 59060-02 B a versatile solution for diverse IT environments.

Security is another critical aspect of the Q-Logic 59060-02 B. The adapter includes built-in features for secure data transmission, including advanced encryption capabilities that protect sensitive information traveling across the network. This focus on security helps organizations safeguard their data integrity and comply with industry regulations.

Another noteworthy characteristic of the Q-Logic 59060-02 B is its robustness and reliability. The HBA is designed to handle rigorous data workloads and can operate in demanding conditions typical of data center environments. With its superior quality and performance capabilities, the Q-Logic 59060-02 B remains a preferred choice for enterprises looking to enhance their data storage and retrieval systems while maintaining high levels of performance and security.