Q-Logic 59060-02 B manual A1003.002F SW2 Zoning Not Supported by other switch, Isolating link

Models: 59060-02 B

1 62
Download 62 pages 21.93 Kb
Page 18
Image 18
(A1003.002F) (SW2 Zoning Not Supported by other switch, Isolating link)

3 – Event Messages Alarm Events

S

(A1003.002D) (Zone Merge response indicates failure to merge, Isolating link)

Meaning:

The attempt to merge two fabrics failed because each active zone

 

set contained a zone with the same name, but different

 

membership.

Action:

Edit the affected zone to remove the conflict or deactivate one of

 

the zone sets.

(A1003.002F) (SW2 Zoning Not Supported by other switch, Isolating link)

Meaning:

The inter-switch link isolated because the local switch is configured

 

for FC-SW-2 compliant zoning (interoperability mode set to

 

Standard), but the remote switch is not.

Action:

Set the interoperability mode on the remote switch to Standard.

(A1003.002E) (Zoning merge has been rejected.)

Meaning:

The attempt to merge two fabrics failed because each active zone

 

set contained a zone with the same name, but different

 

membership.

Action:

Edit the affected zone to remove the conflict or deactivate one of

 

the zone sets.

(A1003.0030) (Zone Merge rejected by remote switch.)

Meaning:

The zone merge failed.

Action:

See the switch log for more details on why the merge failed.

(A1003.0031) (Error reading zoneset from activate direct.)

Meaning:

A device supporting management server has sent an Activate

 

Zoneset Direct $(AZSD) command that did not follow the expected

 

standard layout.

Action:

Contact your authorized maintenance provider.

(A1003.0032) (Zoneset zone_set_name failed validity checks (empty or contains empty zone/alias))

Meaning:

The zone set either has no zones or contains a zone or alias

 

without members.

Action:

Add zones and members, or remove the empty zones and aliases

 

from the zone set.

(A1003.0033) (No memory for command completion)

Meaning:

Insufficient switch memory.

Action:

Contact your authorized maintenance provider.