Q-Logic 59060-02 B manual A1003.003C Incompatible Zoning mode, Isolating link

Models: 59060-02 B

1 62
Download 62 pages 21.93 Kb
Page 20
Image 20
A remote switch sent a merge request that was not understood.

3 – Event Messages Alarm Events

S

(A1003.003B) (Incomplete merge request sequence received, unable to process request.)

Meaning:

A remote switch sent a merge request that was not understood.

Action:

Check the remote switch for configuration errors or equipment

 

malfunction.

(A1003.003C) (Incompatible Zoning mode, Isolating link)

Meaning:

The fabric contains switches with a mix of interoperability mode

 

settings.

Action:

Configure all switches in the fabric to have the same value for

 

interoperability mode.

(A1003.003E) (Security: Ports downed for INVALID_ATTACH require administrative action to be brought online.)

Meaning:

When deactivating a security set, ports that were previously

 

downed due to security violations remain down.

Action:

Reset the ports or place the ports online.

(A1003.003F) (ISL group empty and links up. Set ports offline to activate.)

Meaning:

Attempt at activating fabric binding with an ISL group that has no

 

members is not allowed due because there are inter-switch links

 

(ISL) logged in to the switch.

Action:

Configure all ISLs offline or add each ISL member with fabric

 

binding information to the ISL group before activating.

(A1003.0040) (Zone Member type member_type unsupported.)

Meaning:

An invalid zone member type was discovered in a zone. ACL hard

 

zone membership must be defined by domain_ID and port number.

Action:

Correct the member type.

(A1003.0041) (Zoning objects which contain Fibre Channel (FC) Address Members not being sent to remote switch on save, not supported in this mode)

Meaning:

An attempt was made to assign a zone member by FC address

 

while Interop mode was disabled. When Interop mode is disabled,

 

zone membership must be defined by world wide name or

 

domain_ID and port number.

Action:

Enable Interop mode or change the zone membership type.

3-8

59060-02 B