A

3 – Event Messages Informative Events

(I)(8400.002B) (Switch) (User login account_name is being closed - In-Band connections have been disabled)

Meaning: The session has been closed as a result of a configuration change.

(I) (8400.002C) (Switch) (User login session session_ID user account_name has timed out)

Meaning:

A user login session has ended because of inactivity.

(I) (8400.0036) (Switch) (Hotreset not permitted at this time, try again later)

Meaning:

Conditions exist that will not allow a hotreset. Try again later.

(I)(8400.0037) (Switch) (VIEnable automatically set to False since MFSEnable has been set to True)

Meaning:

Setting the Set Config Port parameter MFSEnable to True

 

automatically sets the Set Config Port parameters VIEnable and

 

LCFEnable to False.

(I)(8400.0038) (Switch) (LCFEnable automatically set to False since MFSEnable has been set to True)

Meaning:

Setting the Set Config Port parameter MFSEnable to True

 

automatically sets the Set Config Port parameters VIEnable and

 

LCFEnable to False.

(I)(8400.0039) (Switch) (MFSEnable automatically set to False since VIEnable has been set to True)

Meaning:

Setting the Set Config Port parameter VIEnable to True

 

automatically sets the Set Config Port parameter MFSEnable to

 

False.

(I)(8400.003A) (Switch) (MFSEnable automatically set to False since LCFEnable has been set to True)

Meaning:

Setting the Set Config Port parameter LCFEnable to True

 

automatically sets the Set Config Port parameter MFSEnable to

 

False.

(I) (8400.003E) (Switch) (Readjusting TempMonitoringWarning from value C to value C)

Meaning:

The temperature threshold at which the switch issues a warning

 

alarm is being changed.

(I) (8400.0040) (Switch) (Readjusting TempMonitoringFailure from value C to value C)

Meaning:

The temperature threshold at which the switch issues a failure

 

alarm is being changed.

59060-02 B

3-47

Page 59
Image 59
Q-Logic 59060-02 B manual Switch Hotreset not permitted at this time, try again later

59060-02 B specifications

The Q-Logic 59060-02 B is a cutting-edge Fibre Channel host bus adapter (HBA) designed to optimize data transfer rates and enhance connectivity in high-performance computing environments. This advanced HBA is particularly suited for enterprise data centers that demand robust and reliable storage solutions, capable of handling large volumes of data with minimal latency.

One of the main features of the Q-Logic 59060-02 B is its dual-channel architecture, which allows for simultaneous data transfer across two separate Fibre Channel connections. This dual-channel capability effectively doubles the data throughput compared to single-channel adapters, providing seamless scalability for growing storage demands. The HBA supports data rates of up to 2 Gbps, ensuring rapid access to storage devices and enhanced performance for applications requiring high bandwidth.

The Q-Logic 59060-02 B also incorporates advanced technologies that enhance its functionality and performance. One such technology is its integrated hardware acceleration for offloading tasks like error correction and flow control from the host CPU. This offloading conserves system resources, allowing the CPU to focus on other critical tasks and improving overall system efficiency.

In addition, the adapter is designed for easy integration with existing storage networks, thanks to its compliance with SCSI standards and support for various operating systems, including Windows and Linux. This compatibility makes the Q-Logic 59060-02 B a versatile solution for diverse IT environments.

Security is another critical aspect of the Q-Logic 59060-02 B. The adapter includes built-in features for secure data transmission, including advanced encryption capabilities that protect sensitive information traveling across the network. This focus on security helps organizations safeguard their data integrity and comply with industry regulations.

Another noteworthy characteristic of the Q-Logic 59060-02 B is its robustness and reliability. The HBA is designed to handle rigorous data workloads and can operate in demanding conditions typical of data center environments. With its superior quality and performance capabilities, the Q-Logic 59060-02 B remains a preferred choice for enterprises looking to enhance their data storage and retrieval systems while maintaining high levels of performance and security.