Admin authority mode was canceled by another user interface session that had the authority to do so.

3 – Event Messages Critical Events

S

(C) (8400.0005) (Switch) (The switch is now performing a hotreset)

Meaning:

Hot reset is in progress.

(C)(8400.0006) (Switch) (Admin mode for user user_name was canceled by user user_name)

Meaning:

(C) (8400.0008) (Switch) (The switch will be reset in several seconds

Meaning:

The switch is being reset as a result of a command from a user

 

interface.

(C) (8400.0009) (Switch) (The switch will hardreset in several seconds)

Meaning:

A hard reset of the switch is pending.

(C) (8400.000A) (Switch) (The switch will hotreset in several seconds)

Meaning:

A hot reset is pending.

(C) (8400.000B) (Switch) (The switch will be shutdown several seconds)

Meaning:

The switch will be shutdown several seconds.

(C) (8400.000C) (Switch) (Configuration is being restored - this could take several minutes)

Meaning:

When a complete configuration restore is done on a switch, a

 

switch reset follows immediately to place the new configuration in

 

effect.

(C) (8400.000D) (Switch) (Attempted feature upgrade of features already installed)

Meaning:

The feature is already installed.

(C) (8400.000E) (Switch) (Upgrading Licensed Ports to number_of_ports)

Meaning:

The number of licensed ports on the switch has been upgraded.

(C)(8400.000F) (Switch) (Attempted Licensed Port upgrade of ports that are already licensed)

Meaning:

The switch has already been upgraded to the number of licensed

 

ports.

(C)(8400.0011) (Switch) (The switch will be reset in several seconds due to a config restore)

Meaning: Switch management is processing a config restore command.

(C) (8400.0012) (Switch) (I/O blade in slot slot_number has been inserted into chassis)

Meaning:

An I/O blade has been inserted into the chassis.

3-34

59060-02 B

Page 46
Image 46
Q-Logic 59060-02 B Switch The switch is now performing a hotreset, Switch The switch will be reset in several seconds

59060-02 B specifications

The Q-Logic 59060-02 B is a cutting-edge Fibre Channel host bus adapter (HBA) designed to optimize data transfer rates and enhance connectivity in high-performance computing environments. This advanced HBA is particularly suited for enterprise data centers that demand robust and reliable storage solutions, capable of handling large volumes of data with minimal latency.

One of the main features of the Q-Logic 59060-02 B is its dual-channel architecture, which allows for simultaneous data transfer across two separate Fibre Channel connections. This dual-channel capability effectively doubles the data throughput compared to single-channel adapters, providing seamless scalability for growing storage demands. The HBA supports data rates of up to 2 Gbps, ensuring rapid access to storage devices and enhanced performance for applications requiring high bandwidth.

The Q-Logic 59060-02 B also incorporates advanced technologies that enhance its functionality and performance. One such technology is its integrated hardware acceleration for offloading tasks like error correction and flow control from the host CPU. This offloading conserves system resources, allowing the CPU to focus on other critical tasks and improving overall system efficiency.

In addition, the adapter is designed for easy integration with existing storage networks, thanks to its compliance with SCSI standards and support for various operating systems, including Windows and Linux. This compatibility makes the Q-Logic 59060-02 B a versatile solution for diverse IT environments.

Security is another critical aspect of the Q-Logic 59060-02 B. The adapter includes built-in features for secure data transmission, including advanced encryption capabilities that protect sensitive information traveling across the network. This focus on security helps organizations safeguard their data integrity and comply with industry regulations.

Another noteworthy characteristic of the Q-Logic 59060-02 B is its robustness and reliability. The HBA is designed to handle rigorous data workloads and can operate in demanding conditions typical of data center environments. With its superior quality and performance capabilities, the Q-Logic 59060-02 B remains a preferred choice for enterprises looking to enhance their data storage and retrieval systems while maintaining high levels of performance and security.