Alarm Events
59060-07  D 2-35
(A1005.011A) (DCBX_PEER_FEATURE_ERROR error: Policy policy_name : reason)
Meaning: Peer on link has detected an error during DCBX [Priority 
Group|Priority Flow Control] exchange.
Action: An error has occurred during the configuration exchange of the 
specified feature. The local and remote configurations are 
incompatible.
(A1005.011C) (DCBX_LINK_DOWNED error: Policy policy_name : reason)
Meaning: The link has been downed by the DCBX protocol.
Action: Consult additional alarms or logs for further information.
(A1005.011D) (DCBX_NO_PER_PRIORITY_FLOW_CONTROL error: Policy policy_name : 
reason)
Meaning: Peer specified no DCBX Priority Flow Control priority for FCoE 
traffic.
Action: The peer Priority Flow Control feature TLV contained no enabled 
priority values. DCBX cannot enable the link until a priority value is 
enabled.
(A1005.011E) (DCBX_MULTI_PER_PRIORITY_FLOW_CONTROL error: Policy policy_name : 
reason)
Meaning: Peer specified multiple DCBX Priority Flow Control priorities ([list of 
values]).
Action: The peer Priority Flow Control feature TLV contained multiple 
enabled priority values. Only a single value is expected. DCBX 
cannot enable the link until a single priority value is enabled.
(A1005.011F) (ENODE_MAC_NOT_CONFIGURED_IN_VLAN error: Policy policy_name : 
reason)
Meaning: An enode mac was not configured in list, not responding to FIP 
request from host.
Action: Configure enode mac within the enode mac list, or configure 
RequireEnodeMacConfig to false so that Enode mac’s are not 
required to be configured.
(A1005.0120) (PT_ADJACENT_SERDES_NOTIFICATION error: Policy policy_name : reason)
Meaning: Port not configured as PT being downed due to sharing hardware 
SerDes with PT port.
Action: Configure port as PT port type if desired to run.