2–Event Messages
Alarm Events
2-46 59060-07 D
(A2001.0003) (blade_id) (Blade fault (SENSOR_FAULT) - CLEARED)
Meaning: The internal fault on the specified Power Supply blade has been
cleared.
Action: None
(A2001.0004) (blade_id) (Blade fault (AC_FAULT) - ALARM CLEARED)
Meaning: The specified Power Supply blade is receiving power.
Action: None
(A2002.0001) (fan_number was removed)
Meaning: A field replaceable fan was removed from the switch.
Action: Reinstall the fan.
(A2002.0002) (Fan fan_blade failure - ALARM SET)
Meaning: A cooling fan has failed.
Action: Replace the fan if it is a customer replaceable unit. Otherwise,
contact your authorized maintenance provider.
(A2002.0003) (Fan or power supply flow mismatch - ALARM SET)
Meaning: The switch has two cooling fans with opposite air flow directions.
Action: Replace one of the fans with another fan with the correct air flow
direction.
(A2003.0001) (fan_blade inserted - ALARM CLEARED)
Meaning: The switch fan blade has been installed and the alarm is cleared.
Action: None
(A2003.0002) (fan_blade OK - ALARM CLEARED)
Meaning: The switch fan blade is operational and the alarm is cleared.
Action: None
(A2003.0003) (Fan flow match - ALARM CLEARED)
Meaning: The opposing fan air flow condition has been corrected.
Action: None
(A2004.0001) (Secondary cpu_blade assuming control of system due to a failure of Primary
cpu_blade)
Meaning: Control is transferring from the primary CPU blade to the
secondary CPU blade on a QLogic 9000 switch.
Action: Investigate the former primary CPU blade for the cause of the
failure.