2–Event Messages
Alarm Events
59060-07 D 2-47
(A2004.0002) (Secondary cpu_blade assuming control of system due to an administrative
switchover)
Meaning: Control is transferring from the primary CPU blade to the
secondary CPU blade on a QLogic 9000 switch.
Action: None
(A2004.0003) (Secondary cpu_blade assuming control of system due to an opening of the
latch or removal of Primary cpu_blade)
Meaning: Control is transferring from the primary CPU blade to the
secondary CPU blade on a QLogic 9000 switch.
Action: None
(A3000.0001) (Temp overheat, sensor_name sensor reads value C - ALARM SET)
Meaning: The chassis temperature has reached a failure threshold.
Action: Check air flow, fan operation, and ambient temperature. If the
problem cannot be corrected, power down the switch.
(A3000.0002) (Temp sensor sensor_name on blade slot_number reads value C - ALARM
SET)
Meaning: The chassis temperature has reached a failure threshold.
Action: Check air flow, fan operation, and ambient temperature. If the
problem cannot be corrected, power down the switch.
(A3001.0001) (Temp overwarm, sensor_name sensor reads value C - ALARM SET)
Meaning: The chassis temperature has reached a warning threshold.
Action: Check air flow, fan operation, and ambient temperature.
(A3002.0001) (sensor name sensor has returned to normal range - ALARM CLEARED)
Meaning: The chassis temperature has returned to the normal range and the
alarm condition has been cleared.
Action: None
(A3002.0002) (Temp sensor sensor_name on blade slot_number reads value C - ALARM
CLEARED)
Meaning: The named blade has returned to the normal operating
temperature range.
Action: None